UA and MCA Doppler Ultrasound Assessment in Late-Onset Uteroplacental Insufficiency

Background: Late-onset uteroplacental insufficiency poses significant risks for adverse perinatal outcomes, as background Doppler ultrasound parameters such as Umbilical Artery (UA) Pulsatility Index (PI), Middle Cerebral Artery (MCA) PI, and the Cerebroplacental Ratio (CPR) are widely used to assess fetal well-being, but their relative diagnostic accuracy remains to be fully clarified where this study aims to evaluate and compare the diagnostic performance of UA PI, MCA PI, and CPR in detecting late-onset uteroplacental insufficiency in a cohort of 100 pregnant women in addition to as a Methods refer to This prospective observational study was conducted from March 2024 to April 2025 where in this study collected One hundred pregnant women diagnosed with late-onset uteroplacental insufficiency after 32 weeks gestation underwent Doppler ultrasound assessments of UA and MCA. CPR was calculated as the ratio of UA PI to MCA PI as well as the prevalence of abnormal Doppler findings was recorded, and diagnostic parameters including sensitivity, specificity, positive and negative predictive values, and odds ratios for adverse outcomes were analyzed using SPSS so as Results were Abnormal CPR was detected in 40% of cases, higher than UA PI (25%) and MCA PI (30%). CPR demonstrated superior sensitivity (90%) and specificity (81.25%) compared to UA PI and MCA PI. The accuracy of CPR was 92%, with a strong association with adverse perinatal outcomes (odds ratio 9.1). CPR also showed higher predictive value for neonatal complications such as NICU admission and fetal distress. Finally, we concluded that CPR is a more sensitive and accurate Doppler parameter than UA PI or MCA PI alone for diagnosing late-onset uteroplacental insufficiency. Incorporating CPR into routine fetal Doppler assessment may enhance early detection and improve perinatal outcomes in affected pregnancies.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-08-04
DOI
https://doi.org/10.5281/zenodo.16968867
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

UA and MCA Doppler Ultrasound Assessment in Late-Onset Uteroplacental Insufficiency

Zenodo (CERN European Organization for Nuclear Research)
Geochemistry and Geologic Mapping
article

UA and MCA Doppler Ultrasound Assessment in Late-Onset Uteroplacental Insufficiency

article en

Abstract

Background: Late-onset uteroplacental insufficiency poses significant risks for adverse perinatal outcomes, as background Doppler ultrasound parameters such as Umbilical Artery (UA) Pulsatility Index (PI), Middle Cerebral Artery (MCA) PI, and the Cerebroplacental Ratio (CPR) are widely used to assess fetal well-being, but their relative diagnostic accuracy remains to be fully clarified where this study aims to evaluate and compare the diagnostic performance of UA PI, MCA PI, and CPR in detecting late-onset uteroplacental insufficiency in a cohort of 100 pregnant women in addition to as a Methods refer to This prospective observational study was conducted from March 2024 to April 2025 where in this study collected One hundred pregnant women diagnosed with late-onset uteroplacental insufficiency after 32 weeks gestation underwent Doppler ultrasound assessments of UA and MCA. CPR was calculated as the ratio of UA PI to MCA PI as well as the prevalence of abnormal Doppler findings was recorded, and diagnostic parameters including sensitivity, specificity, positive and negative predictive values, and odds ratios for adverse outcomes were analyzed using SPSS so as Results were Abnormal CPR was detected in 40% of cases, higher than UA PI (25%) and MCA PI (30%). CPR demonstrated superior sensitivity (90%) and specificity (81.25%) compared to UA PI and MCA PI. The accuracy of CPR was 92%, with a strong association with adverse perinatal outcomes (odds ratio 9.1). CPR also showed higher predictive value for neonatal complications such as NICU admission and fetal distress. Finally, we concluded that CPR is a more sensitive and accurate Doppler parameter than UA PI or MCA PI alone for diagnosing late-onset uteroplacental insufficiency. Incorporating CPR into routine fetal Doppler assessment may enhance early detection and improve perinatal outcomes in affected pregnancies.

Zenodo (CERN European Organization for Nuclear Research)
Thi Qar University (IQ), Directorate of Health (IS)
Good health and well-being
Openalex Percentile: Top 62%
Geochemistry and Geologic Mapping
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

UA and MCA Doppler Ultrasound Assessment in Late-Onset Uteroplacental Insufficiency · Zenodo (CERN European Organization for Nuclear Research) (2025) | TGRS Research Map | TGRS