Measurement System for Human Lateral Mandibular Forces

Lateral mandibular movement is essential for grinding previously ingested food. By measuring the maximum lateral force of the mandible, it is possible to quantify the functionality of this important movement. However, state-of-the-art force sensors utilize the force application through the teeth, causing unknown measurement uncertainties, and, thus, making them unsuitable for qualitative measurements. We present a lateral force measurement system with a nominal force of 200N and an accuracy of 0.5%, which is capable of measuring protrusive forces as well. The connection between the jaw and the measuring system is established by a mandibular brace, which is located under the subject’s jaw. The brace is interchangeable and can be customized for each individual subject to ensure optimal force application. A three-dimensional force sensor measures forces of the mandible in every translational direction. The measurement system is validated with a study of eight subjects. The maximum measured isometric forces of the mandible are 31.47 ± 11.00N in lateral left direction, 37.32 ± 22.10N in lateral right direction, and 82.96 ± 16.14N in protrusive direction. The system builds a promising basis for measuring a variety of mandibular force parameters, allowing a deeper insight into the subject’s masticatory system.

Publication Details

Journal
TUbilio (Technical University of Darmstadt)
Published
2025-01-01
DOI
https://doi.org/10.26083/tuprints-00031135
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurement System for Human Lateral Mandibular Forces

TUbilio (Technical University of Darmstadt)
Geochemistry and Geologic Mapping
article

Measurement System for Human Lateral Mandibular Forces

article en

Abstract

Lateral mandibular movement is essential for grinding previously ingested food. By measuring the maximum lateral force of the mandible, it is possible to quantify the functionality of this important movement. However, state-of-the-art force sensors utilize the force application through the teeth, causing unknown measurement uncertainties, and, thus, making them unsuitable for qualitative measurements. We present a lateral force measurement system with a nominal force of 200N and an accuracy of 0.5%, which is capable of measuring protrusive forces as well. The connection between the jaw and the measuring system is established by a mandibular brace, which is located under the subject’s jaw. The brace is interchangeable and can be customized for each individual subject to ensure optimal force application. A three-dimensional force sensor measures forces of the mandible in every translational direction. The measurement system is validated with a study of eight subjects. The maximum measured isometric forces of the mandible are 31.47 ± 11.00N in lateral left direction, 37.32 ± 22.10N in lateral right direction, and 82.96 ± 16.14N in protrusive direction. The system builds a promising basis for measuring a variety of mandibular force parameters, allowing a deeper insight into the subject’s masticatory system.

TUbilio (Technical University of Darmstadt)
Zero hunger
Openalex Percentile: Top 63%
Geochemistry and Geologic Mapping
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Measurement System for Human Lateral Mandibular Forces · TUbilio (Technical University of Darmstadt) (2025) | TGRS Research Map | TGRS