Adaptive multi-objective real-time hierarchical control for isolated microgrid clusters utilizing an enhanced particle swarm optimization strategy to optimize costs and emissions

• Proposes a novel adaptive hierarchical control for IMGCs. • Optimizes energy distribution and operation within MGs using MOPSO. • Minimizes CO2 emissions and total losses simultaneously. • Demonstrates superior performance and robustness in simulations and hardware-in-the-loop experiments. This paper introduces an adaptive hierarchical control for an isolated microgrid cluster (IMGC) leveraging a real-time multi-objective particle swarm optimization (MOPSO) algorithm. It simultaneously considers CO 2 emissions minimization as a tertiary control objective and total losses minimization as a primary control objective, integrating grid-supporting and grid-feeding inverters for MG interconnection. The effectiveness of the MOPSO-based hierarchical control is demonstrated across multiple scenarios. Compared to a hierarchical control based on proportional power distribution relative to the rated inverter capacities of the MGs, the proposed method shows a 27.21% reduction in total losses and a 7.66% reduction in CO 2 emissions. When compared with an optimization based on the fmincon solver, the proposed approach achieves a 22.92% reduction in losses and a 3.5% decrease in emissions. Additionally, centralized secondary control improves MRE indices by 100.09%, ITAE by 28.5%, ITSE by 43.78%, IAE by 30.61%, and ITSE by 47.72%, compared to the primary control strategy based on proportional approach. The MOPSO approach demonstrates robustness and flexibility, maintaining stable frequency and voltage within set thresholds during MG failures and sudden demand changes. Finally, the practical feasibility of the proposed approach is verified in a hardware-in-the-loop experimental setup using an OPAL-RT4512 unit and a dSPACE MicroLabBox. The experimental results, utilizing a time step of 50 µs, are consistent with the simulation outcomes, ensuring voltage and frequency control as its rated references.

Institutions

Publication Details

Journal
Electric Power Systems Research
Published
2025-08-28
DOI
https://doi.org/10.1016/j.epsr.2025.112169
Citations
2
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
4.96

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Adaptive multi-objective real-time hierarchical control for isolated microgrid clusters utilizing an enhanced particle swarm optimization strategy to optimize costs and emissions

2 citations
Electric Power Systems Research
Geochemistry and Geologic Mapping
4.96
article

Adaptive multi-objective real-time hierarchical control for isolated microgrid clusters utilizing an enhanced particle swarm optimization strategy to optimize costs and emissions

article en
2 citations

Abstract

• Proposes a novel adaptive hierarchical control for IMGCs. • Optimizes energy distribution and operation within MGs using MOPSO. • Minimizes CO2 emissions and total losses simultaneously. • Demonstrates superior performance and robustness in simulations and hardware-in-the-loop experiments. This paper introduces an adaptive hierarchical control for an isolated microgrid cluster (IMGC) leveraging a real-time multi-objective particle swarm optimization (MOPSO) algorithm. It simultaneously considers CO 2 emissions minimization as a tertiary control objective and total losses minimization as a primary control objective, integrating grid-supporting and grid-feeding inverters for MG interconnection. The effectiveness of the MOPSO-based hierarchical control is demonstrated across multiple scenarios. Compared to a hierarchical control based on proportional power distribution relative to the rated inverter capacities of the MGs, the proposed method shows a 27.21% reduction in total losses and a 7.66% reduction in CO 2 emissions. When compared with an optimization based on the fmincon solver, the proposed approach achieves a 22.92% reduction in losses and a 3.5% decrease in emissions. Additionally, centralized secondary control improves MRE indices by 100.09%, ITAE by 28.5%, ITSE by 43.78%, IAE by 30.61%, and ITSE by 47.72%, compared to the primary control strategy based on proportional approach. The MOPSO approach demonstrates robustness and flexibility, maintaining stable frequency and voltage within set thresholds during MG failures and sudden demand changes. Finally, the practical feasibility of the proposed approach is verified in a hardware-in-the-loop experimental setup using an OPAL-RT4512 unit and a dSPACE MicroLabBox. The experimental results, utilizing a time step of 50 µs, are consistent with the simulation outcomes, ensuring voltage and frequency control as its rated references.

Electric Power Systems ResearchVol. 250
Universidad de Jaén (ES), Universidad de Cádiz (ES), Clínica Diagonal (ES), Universitat Politècnica de Catalunya (ES)
Ministerio de Ciencia e Innovación, Agencia Estatal de Investigación
Affordable and clean energy
Openalex Percentile: Top 4%
Geochemistry and Geologic Mapping
4.96
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.