The Irregular Response of Flat Plate Structures to Horizontal Deformation for Engineering Decisions

This study examines the structural response of a seven-story reinforced concrete building with a dual system, focusing on shear forces, stiffness, and inter-story variations. Designed in accordance with SNI 1726-2019 for Jakarta, the study considers dead loads, live loads, wind loads, rain loads, and earthquake loads. Analysis on the second floor (6.2 m above the foundation) indicates that the inter-story deflections meet the permissible limits, with a maximum deviation of 64.615 kN at the roof and 49.23 kN from floors 2 to 6. Static shear forces reached 41,826.62 kN (X) and 4,182.62 kN (Y), while dynamic shear forces reached 4,697.28 kN (X) and 5,057.97 kN (Y), meeting the static force requirement of 100%. Overall, the shear forces, stiffness, and inter-story deviations of Building B demonstrate an effective structural response to earthquake activity. Engineers are expected to master the behavior of irregularities in structural elements due to earthquake loads so that they can make informed decisions in construction planning and its implementation in the field.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-08-25
DOI
https://doi.org/10.5281/zenodo.16947257
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Irregular Response of Flat Plate Structures to Horizontal Deformation for Engineering Decisions

Zenodo (CERN European Organization for Nuclear Research)
Geochemistry and Geologic Mapping
article

The Irregular Response of Flat Plate Structures to Horizontal Deformation for Engineering Decisions

article en

Abstract

This study examines the structural response of a seven-story reinforced concrete building with a dual system, focusing on shear forces, stiffness, and inter-story variations. Designed in accordance with SNI 1726-2019 for Jakarta, the study considers dead loads, live loads, wind loads, rain loads, and earthquake loads. Analysis on the second floor (6.2 m above the foundation) indicates that the inter-story deflections meet the permissible limits, with a maximum deviation of 64.615 kN at the roof and 49.23 kN from floors 2 to 6. Static shear forces reached 41,826.62 kN (X) and 4,182.62 kN (Y), while dynamic shear forces reached 4,697.28 kN (X) and 5,057.97 kN (Y), meeting the static force requirement of 100%. Overall, the shear forces, stiffness, and inter-story deviations of Building B demonstrate an effective structural response to earthquake activity. Engineers are expected to master the behavior of irregularities in structural elements due to earthquake loads so that they can make informed decisions in construction planning and its implementation in the field.

Zenodo (CERN European Organization for Nuclear Research)
National Society of Professional Engineers (US), Warmadewa University (ID)
Sustainable cities and communities
Openalex Percentile: Top 64%
Geochemistry and Geologic Mapping
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.