ICP-SWAn: A selective waveform analysis pipeline for conformal subpeak detection in intracranial pressure signals

Intensive care unit management of patients with traumatic brain injury or aneurysmal hemorrhage often requires intracranial pressure (ICP) monitoring. Although the primary goal is to prevent adverse intracranial hypertensive events, mechanical properties of the cerebrospinal system can also be derived from a closer analysis of the ICP signal. The morphology of the ICP signal can be influenced by a variety of physiological components and is therefore highly variable. In particular, on the time scale of a heartbeat, characteristic subpeaks called P1, P2, and P3 are visible most of the time and their analysis may provide valuable insights about cerebrospinal pressure–volume compensation. However, their automatic detection in real time is a challenging task that requires displaying no result in situations of uncertainty to avoid misleading the clinicians. Therefore, we applied several results from the “Learn-then-Test” theoretical framework to our deep learning-based delineation algorithm to identify cases where it is appropriate to refrain from providing a result. The subpeak detection task was performed using recurrent neural networks trained on a 59-patient dataset. Performance was evaluated on two independent test datasets. The first one consisted of 13,086 pulses extracted from 49 recordings and labeled by 3 independent operators. The second one, which is publicly available, consisted of 11,172 pulses extracted from 63 recordings. The mean absolute error on the calculated P2/P1 ratio was 0.061 for the first test dataset and 0.016 for the second test dataset. • In an online setting, P2/P1 ratio calculation should include proper quality control. • Certain precautions must be taken when performing real-time ICP signal analysis. • The benefits of conformal risk control are mostly seeable in a noisy environment.

Institutions

Publication Details

Journal
Biomedical Signal Processing and Control
Published
2025-08-27
DOI
https://doi.org/10.1016/j.bspc.2025.108603
Primary Topic
Traumatic Brain Injury and Neurovascular Disturbances
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ICP-SWAn: A selective waveform analysis pipeline for conformal subpeak detection in intracranial pressure signals

Biomedical Signal Processing and Control
Traumatic Brain Injury and Neurovascular Disturbances
article

ICP-SWAn: A selective waveform analysis pipeline for conformal subpeak detection in intracranial pressure signals

article en

Abstract

Intensive care unit management of patients with traumatic brain injury or aneurysmal hemorrhage often requires intracranial pressure (ICP) monitoring. Although the primary goal is to prevent adverse intracranial hypertensive events, mechanical properties of the cerebrospinal system can also be derived from a closer analysis of the ICP signal. The morphology of the ICP signal can be influenced by a variety of physiological components and is therefore highly variable. In particular, on the time scale of a heartbeat, characteristic subpeaks called P1, P2, and P3 are visible most of the time and their analysis may provide valuable insights about cerebrospinal pressure–volume compensation. However, their automatic detection in real time is a challenging task that requires displaying no result in situations of uncertainty to avoid misleading the clinicians. Therefore, we applied several results from the “Learn-then-Test” theoretical framework to our deep learning-based delineation algorithm to identify cases where it is appropriate to refrain from providing a result. The subpeak detection task was performed using recurrent neural networks trained on a 59-patient dataset. Performance was evaluated on two independent test datasets. The first one consisted of 13,086 pulses extracted from 49 recordings and labeled by 3 independent operators. The second one, which is publicly available, consisted of 11,172 pulses extracted from 63 recordings. The mean absolute error on the calculated P2/P1 ratio was 0.061 for the first test dataset and 0.016 for the second test dataset. • In an online setting, P2/P1 ratio calculation should include proper quality control. • Certain precautions must be taken when performing real-time ICP signal analysis. • The benefits of conformal risk control are mostly seeable in a noisy environment.

Biomedical Signal Processing and ControlVol. 112
Wrocław University of Science and Technology (PL), Centre National de la Recherche Scientifique (FR), Franche-Comté Électronique Mécanique Thermique et Optique - Sciences et Technologies (FR), Hôpital Pierre Wertheimer (FR), Institut UTINAM (FR), Institut des Sciences Moléculaires d'Orsay (FR), Laboratoire de Mathématiques Blaise Pascal (FR), Université Marie et Louis Pasteur (FR), AGH University of Krakow (PL), Université de Franche-Comté (FR)
Quality Education
Openalex Percentile: Top 39%
Traumatic Brain Injury and Neurovascular Disturbances
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.