Distal Fibula Fracture Treatment with Intramedullary Implant: Concept Assessment and Initial Verification

This study examined the biomechanical performance of intramedullary nail implants for distal fibula fractures, particularly Weber B fractures. Simplified three-dimensional models were created to simulate the biomechanics of the leg during standing. Simulations were conducted with an axial load of 70 Newtons, with the fibula bearing 20 % of the total load from the body weight shared evenly between both legs. The results demonstrated that the intramedullary nail exhibited significantly lower stress levels compared to the traditional plate and screw construct. Peak Von Mises stress levels were 26 MPa in the nail’s syndesmotic screw and 146 MPa at the screw-to-plate interface within the plate construct. These findings provide a rationale for the hypothesis that patients may be able to bear weight earlier after surgery.

Institutions

Publication Details

Journal
Infinite Science GmbH
Published
2025-01-22
DOI
https://doi.org/10.18416/scp.2025.1928
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Distal Fibula Fracture Treatment with Intramedullary Implant: Concept Assessment and Initial Verification

Infinite Science GmbH
Geochemistry and Geologic Mapping
article

Distal Fibula Fracture Treatment with Intramedullary Implant: Concept Assessment and Initial Verification

article en

Abstract

This study examined the biomechanical performance of intramedullary nail implants for distal fibula fractures, particularly Weber B fractures. Simplified three-dimensional models were created to simulate the biomechanics of the leg during standing. Simulations were conducted with an axial load of 70 Newtons, with the fibula bearing 20 % of the total load from the body weight shared evenly between both legs. The results demonstrated that the intramedullary nail exhibited significantly lower stress levels compared to the traditional plate and screw construct. Peak Von Mises stress levels were 26 MPa in the nail’s syndesmotic screw and 146 MPa at the screw-to-plate interface within the plate construct. These findings provide a rationale for the hypothesis that patients may be able to bear weight earlier after surgery.

Infinite Science GmbH
Institute for Integrative and Experimental Genomics (DE), University Hospital Schleswig-Holstein (DE), Stryker (Germany) (DE), University of Lübeck (DE)
Openalex Percentile: Top 66%
Geochemistry and Geologic Mapping
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Distal Fibula Fracture Treatment with Intramedullary Implant: Concept Assessment and Initial Verification · Infinite Science GmbH (2025) | TGRS Research Map | TGRS