Percival soft X-ray CMOS Imager for Photon Science – Status and Prospects

Percival is a CMOS-based imager with 2 megapixels, also called P2M, designed for photon science experiments. The first generation of the P2M sensor showed some performance issues. Specifically, ADCs in full-speed operation mode are affected by crosstalk and show a non-linear and uncorrectable response. A firmware hack to the readout and data acquisition system has been introduced to partially overcome these effects, at the cost of limiting the frame rate to 83 Hz. Moreover, a non-uniform dark response of the sensor pixels is observed, explained by non-uniform bias currents across the chip: two opposite edges of the sensor cannot be digitized when applying biases that have the centre of the sensor operating normally. These issues are addressed in the re-submission of the chip. In this contribution, we present the current status of the detector and the first results from the re-designed sensor.

Publication Details

Journal
KITopen
Published
2025-01-01
DOI
https://doi.org/10.5445/ir/1000184176
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Percival soft X-ray CMOS Imager for Photon Science – Status and Prospects

KITopen
Geochemistry and Geologic Mapping
article

Percival soft X-ray CMOS Imager for Photon Science – Status and Prospects

article en

Abstract

Percival is a CMOS-based imager with 2 megapixels, also called P2M, designed for photon science experiments. The first generation of the P2M sensor showed some performance issues. Specifically, ADCs in full-speed operation mode are affected by crosstalk and show a non-linear and uncorrectable response. A firmware hack to the readout and data acquisition system has been introduced to partially overcome these effects, at the cost of limiting the frame rate to 83 Hz. Moreover, a non-uniform dark response of the sensor pixels is observed, explained by non-uniform bias currents across the chip: two opposite edges of the sensor cannot be digitized when applying biases that have the centre of the sensor operating normally. These issues are addressed in the re-submission of the chip. In this contribution, we present the current status of the detector and the first results from the re-designed sensor.

KITopen
Openalex Percentile: Top 67%
Geochemistry and Geologic Mapping
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.