Scintillator-based SiPM Detector: Improved Performance by Equalization of Pulse Arrival Times

A desired temporal accuracy of scintillator-based detectors is less than 100 ps. In medical imaging, this is necessary for successful time-of-flight positron emission tomography (TOF-PET) measurements. In high-energy physics, the calorimeter time resolution must also be on the order of tens of picoseconds. In this work we describe a way to achieve such a high level of performance for a detector consisting of a monolithic scintillator that distributes light over several cells of an analog silicon photomultiplier (SiPM) array. Each of the cells is read and analyzed separately, applying a waveform sampling (WFS)technique combined with a nonlinear rise approximation (nLRA).Initially, due to a specific spatiotemporal distribution of photons in the scintillator as well as saturation and recovery effects inherent to SiPMs, the spread of arrival times deduced from signals of different cells can exceed 1 ns for the same array and the same event. To improve the timing performance we propose a method of equalization of arrival times for predominantly illuminated cells in the same SiPM array. This results in a coincidence time resolution (CTR) below 100 ps FWHM for a pair of identical detectors

Institutions

Publication Details

Journal
JuSER Publikationsportal
Published
2025-01-01
DOI
https://doi.org/10.34734/fzj-2025-03029
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Scintillator-based SiPM Detector: Improved Performance by Equalization of Pulse Arrival Times

JuSER Publikationsportal
Geochemistry and Geologic Mapping
article

Scintillator-based SiPM Detector: Improved Performance by Equalization of Pulse Arrival Times

article en

Abstract

A desired temporal accuracy of scintillator-based detectors is less than 100 ps. In medical imaging, this is necessary for successful time-of-flight positron emission tomography (TOF-PET) measurements. In high-energy physics, the calorimeter time resolution must also be on the order of tens of picoseconds. In this work we describe a way to achieve such a high level of performance for a detector consisting of a monolithic scintillator that distributes light over several cells of an analog silicon photomultiplier (SiPM) array. Each of the cells is read and analyzed separately, applying a waveform sampling (WFS)technique combined with a nonlinear rise approximation (nLRA).Initially, due to a specific spatiotemporal distribution of photons in the scintillator as well as saturation and recovery effects inherent to SiPMs, the spread of arrival times deduced from signals of different cells can exceed 1 ns for the same array and the same event. To improve the timing performance we propose a method of equalization of arrival times for predominantly illuminated cells in the same SiPM array. This results in a coincidence time resolution (CTR) below 100 ps FWHM for a pair of identical detectors

JuSER Publikationsportal
Forschungszentrum Jülich (DE), Thomas Jefferson National Accelerator Facility (US)
Affordable and clean energy
Openalex Percentile: Top 67%
Geochemistry and Geologic Mapping
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Scintillator-based SiPM Detector: Improved Performance by Equalization of Pulse Arrival Times · JuSER Publikationsportal (2025) | TGRS Research Map | TGRS