Lymphoma Therapy Response Assessment with Low-Dose [18F]FDG Total-Body PET/CT.

The improved sensitivity of total-body (TB) PET/CT offers the possibility of reducing injected activities. The aim of our study was to define a lower limit of reduced injected activities in [18F]FDG TB PET/CT for interim and end-of-treatment assessment of patients with lymphoma at 2 acquisition times. Methods: Twenty-four consecutive patients with lymphoma who were undergoing interim and end-of-treatment TB PET/CT were prospectively enrolled in this study. An [18F]FDG activity of 3.0 MBq/kg served as the reference standard (RS). Images simulating low doses of 1.0, 0.5, 0.25, and 0.125 MBq/kg were reconstructed at 1 and 2 h after injection. The coefficient of variation of the liver was assessed. Lymphoma lesions were segmented and semiquantitatively compared with the RS using the SUV. Additionally, metabolic tumor volume (MTV) for each lesion, patient-based total MTV, and total-lesion glycolysis (TLG) were analyzed. Semiquantitative parameters were normalized to the liver and blood pool by tumor-to-background ratios (TBRs) and contrast-to-noise ratios. Therapy response was assessed using Deauville criteria. Results: Overall, 191 lymphoma lesions were analyzed. SUVmax demonstrated a trend toward a statistically significant increase in scans with reduced activity at 1 h after injection (6.28 ± 5.87 for RS vs. 7.76 ± 6.69 for 0.125 MBq/kg; P = 0.07) and 2 h after injection (7.14 ± 7.16 for RS vs. 8.67 ± 7.62 for 0.125 MBq/kg; P = 0.13). SUVpeak, SUVmean, MTV, and TLG did not significantly differ between the reduced injected activities and the RS. The coefficient of variation for the liver increased significantly with decreasing injected activities (P < 0.01). The TBR for the liver did not differ significantly, whereas the TBR for the blood pool was significantly higher only for the lowest injected activity (P < 0.01) at 2 h after injection. The contrast-to-noise ratio significantly decreased with reduced activities. Deauville scores did not differ significantly, up to a dose of 0.25 MBq/kg at 1 h after injection and a dose of 1.0 MBq/kg at 2 h after injection. Below this limit, we noted significantly lower Deauville scores for reduced injected activities (P < 0.01). Conclusion: Reduction of injected activities with [18F]FDG TB PET/CT for therapy response assessment in patients with lymphoma may be possible and does not result in significant differences in MTV, TBR, or TLG. SUVmax and Deauville scores were comparable to the RS to a lower limit of 0.25 MBq/kg at 1 h after injection and 1.0 MBq/kg at 2 h after injection.

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2025-08-20
DOI
https://doi.org/10.48620/90809
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Lymphoma Therapy Response Assessment with Low-Dose [18F]FDG Total-Body PET/CT.

Open Access CRIS of the University of Bern
Geochemistry and Geologic Mapping
article

Lymphoma Therapy Response Assessment with Low-Dose [18F]FDG Total-Body PET/CT.

article en

Abstract

The improved sensitivity of total-body (TB) PET/CT offers the possibility of reducing injected activities. The aim of our study was to define a lower limit of reduced injected activities in [18F]FDG TB PET/CT for interim and end-of-treatment assessment of patients with lymphoma at 2 acquisition times. Methods: Twenty-four consecutive patients with lymphoma who were undergoing interim and end-of-treatment TB PET/CT were prospectively enrolled in this study. An [18F]FDG activity of 3.0 MBq/kg served as the reference standard (RS). Images simulating low doses of 1.0, 0.5, 0.25, and 0.125 MBq/kg were reconstructed at 1 and 2 h after injection. The coefficient of variation of the liver was assessed. Lymphoma lesions were segmented and semiquantitatively compared with the RS using the SUV. Additionally, metabolic tumor volume (MTV) for each lesion, patient-based total MTV, and total-lesion glycolysis (TLG) were analyzed. Semiquantitative parameters were normalized to the liver and blood pool by tumor-to-background ratios (TBRs) and contrast-to-noise ratios. Therapy response was assessed using Deauville criteria. Results: Overall, 191 lymphoma lesions were analyzed. SUVmax demonstrated a trend toward a statistically significant increase in scans with reduced activity at 1 h after injection (6.28 ± 5.87 for RS vs. 7.76 ± 6.69 for 0.125 MBq/kg; P = 0.07) and 2 h after injection (7.14 ± 7.16 for RS vs. 8.67 ± 7.62 for 0.125 MBq/kg; P = 0.13). SUVpeak, SUVmean, MTV, and TLG did not significantly differ between the reduced injected activities and the RS. The coefficient of variation for the liver increased significantly with decreasing injected activities (P < 0.01). The TBR for the liver did not differ significantly, whereas the TBR for the blood pool was significantly higher only for the lowest injected activity (P < 0.01) at 2 h after injection. The contrast-to-noise ratio significantly decreased with reduced activities. Deauville scores did not differ significantly, up to a dose of 0.25 MBq/kg at 1 h after injection and a dose of 1.0 MBq/kg at 2 h after injection. Below this limit, we noted significantly lower Deauville scores for reduced injected activities (P < 0.01). Conclusion: Reduction of injected activities with [18F]FDG TB PET/CT for therapy response assessment in patients with lymphoma may be possible and does not result in significant differences in MTV, TBR, or TLG. SUVmax and Deauville scores were comparable to the RS to a lower limit of 0.25 MBq/kg at 1 h after injection and 1.0 MBq/kg at 2 h after injection.

Open Access CRIS of the University of Bern
Good health and well-being
Openalex Percentile: Top 68%
Geochemistry and Geologic Mapping
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.