Transcatheter Aortic Valve Replacement With Balloon- Versus Self-Expandable Bioprostheses for the Treatment of Bicuspid Aortic Valve Stenosis.

Background Differences between balloon- and self-expandable transcatheter heart valves (BE-THVs and SE-THVs, respectively) may influence the outcomes of transcatheter aortic valve replacement for bicuspid aortic valve (BAV) stenosis.Methods Consecutive patients undergoing transcatheter aortic valve replacement with BE-THV or SE-THV for computed tomography-diagnosed bicuspid aortic valve stenosis at 29 centers were included. The primary outcome was death or stroke. After propensity score matching in 10 data sets generated by multiple imputation, outcomes from transcatheter aortic valve replacement to 3-year follow-up were computed by multivariable binomial logistic mixed-effects models, multivariable linear mixed-effects models, or multivariable frailty models accounting for center-related influences and residual confounding effects (doubly robust adjustment). The results were replicated by inverse probability of treatment weighting and multivariable adjustment.Results A total of 1443 consecutive patients with bicuspid aortic valve stenosis undergoing BE-THV (n=860) or SE-THV (n=583) implantation were included. In-hospital and 30-day death or stroke did not significantly differ between BE-THV and SE-THV groups (5.1% versus 6.1%; hazard ratio for propensity score matching, 1.02 [95% CI, 0.51-2.02]). BE-THV implantation was associated with higher annulus rupture and mean transvalvular gradient compared with SE-THV implantation. In contrast, SE-THV implantation was associated with higher additional valve implantation and paravalvular regurgitation compared with BE-THV implantation. The results were consistent across the statistical methods used and between early- and new-generation THVs. At 30 days, pacemaker implantation was lower in the BE-THV group compared with the SE-THV group (11.9% versus 18.6%; hazard ratio for propensity score matching, 0.58 [95% CI, 0.36-0.93]). This result did not depend on the statistical method used. At 3 years, consistent with 1- and 2-year analyses, death or stroke was not significantly different between the BE-THV and SE-THV groups (23.7% versus 26.2%; hazard ratio for propensity score matching, 0.99 [95% CI, 0.65-1.51]). Death or stroke across major clinical, anatomical, functional, and procedural conditions was consistent with the main analysis. After inverse probability of treatment weighting and multivariable adjustment, these conclusions remained unchanged.Conclusions In patients undergoing transcatheter aortic valve replacement for bicuspid aortic valve stenosis, death or stroke does not significantly differ between those receiving a BE-THV and those receiving an SE-THV over a follow-up of 3 years. BE-THV is associated with higher transvalvular mean gradient and more frequent annulus rupture, whereas SE-THV is associated with more frequent moderate to severe aortic regurgitation, additional THV implantation, and permanent pacemaker implantation.

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2025-08-20
DOI
https://doi.org/10.48620/90788
Primary Topic
Diverse Scientific and Economic Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Transcatheter Aortic Valve Replacement With Balloon- Versus Self-Expandable Bioprostheses for the Treatment of Bicuspid Aortic Valve Stenosis.

Open Access CRIS of the University of Bern
Diverse Scientific and Economic Studies
article

Transcatheter Aortic Valve Replacement With Balloon- Versus Self-Expandable Bioprostheses for the Treatment of Bicuspid Aortic Valve Stenosis.

article en

Abstract

Background Differences between balloon- and self-expandable transcatheter heart valves (BE-THVs and SE-THVs, respectively) may influence the outcomes of transcatheter aortic valve replacement for bicuspid aortic valve (BAV) stenosis.Methods Consecutive patients undergoing transcatheter aortic valve replacement with BE-THV or SE-THV for computed tomography-diagnosed bicuspid aortic valve stenosis at 29 centers were included. The primary outcome was death or stroke. After propensity score matching in 10 data sets generated by multiple imputation, outcomes from transcatheter aortic valve replacement to 3-year follow-up were computed by multivariable binomial logistic mixed-effects models, multivariable linear mixed-effects models, or multivariable frailty models accounting for center-related influences and residual confounding effects (doubly robust adjustment). The results were replicated by inverse probability of treatment weighting and multivariable adjustment.Results A total of 1443 consecutive patients with bicuspid aortic valve stenosis undergoing BE-THV (n=860) or SE-THV (n=583) implantation were included. In-hospital and 30-day death or stroke did not significantly differ between BE-THV and SE-THV groups (5.1% versus 6.1%; hazard ratio for propensity score matching, 1.02 [95% CI, 0.51-2.02]). BE-THV implantation was associated with higher annulus rupture and mean transvalvular gradient compared with SE-THV implantation. In contrast, SE-THV implantation was associated with higher additional valve implantation and paravalvular regurgitation compared with BE-THV implantation. The results were consistent across the statistical methods used and between early- and new-generation THVs. At 30 days, pacemaker implantation was lower in the BE-THV group compared with the SE-THV group (11.9% versus 18.6%; hazard ratio for propensity score matching, 0.58 [95% CI, 0.36-0.93]). This result did not depend on the statistical method used. At 3 years, consistent with 1- and 2-year analyses, death or stroke was not significantly different between the BE-THV and SE-THV groups (23.7% versus 26.2%; hazard ratio for propensity score matching, 0.99 [95% CI, 0.65-1.51]). Death or stroke across major clinical, anatomical, functional, and procedural conditions was consistent with the main analysis. After inverse probability of treatment weighting and multivariable adjustment, these conclusions remained unchanged.Conclusions In patients undergoing transcatheter aortic valve replacement for bicuspid aortic valve stenosis, death or stroke does not significantly differ between those receiving a BE-THV and those receiving an SE-THV over a follow-up of 3 years. BE-THV is associated with higher transvalvular mean gradient and more frequent annulus rupture, whereas SE-THV is associated with more frequent moderate to severe aortic regurgitation, additional THV implantation, and permanent pacemaker implantation.

Open Access CRIS of the University of Bern
Good health and well-being
Openalex Percentile: Top 36%
Diverse Scientific and Economic Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.