Система моніторингу зчитування моргання з використанням магнітних властивостей ферофлюїду

The object of the study is an eye movement monitoring system based on a combination of a permanent magnet, ferrofluid and glasses with built-in inductive sensors. In the current conditions of development of wearable technologies and biomedical devices, such a system has the potential for application in medicine, in particular for monitoring eye movements in real time, which can be useful for diagnostics and rehabilitation. The problem considered in the study is to create a compact, comfortable and accurate system for non-contact monitoring of the frequency and nature of blinking. The main attention is paid to optimizing the design of the eyeglass frame with built-in coils, as well as the development of algorithms for collecting and processing induced signals, which allows for effective detection of eye movements without discomfort for the user. The essence of the results obtained is the development of a wearable system that uses ferrofluid applied to false eyelashes and magnetic coils built into a 3D-printed eyeglass frame. Experimental tests demonstrated the system’s ability to clearly distinguish between slow and fast blinking based on induced signals obtained using an Arduino Uno board with a reading frequency of 200 Hz. It was found that the amplitude of the signals during fast blinking is significantly higher, which ensures reliable tracking of eye movements in different modes. The results are explained by the innovative combination of a contactless magnetic sensor with a liquid form of ferrofluid, which ensures flexibility, comfort and invisibility of the system. Coils built into the frame allow for amplification of the induction signal, reducing the impact of noise and improving data quality. The use of a 3D model of the frame optimized for coil fixation ensures design reliability and repeatability of the results. The innovation of the approach lies in the combination of advanced materials and 3D printing technologies with traditional electronic solutions to create a compact and convenient eye movement monitoring device. The proposed system is a promising tool for further application in medical, rehabilitation and interface technologies, where precise control of blinking is critically important.

Institutions

Publication Details

Journal
The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy
Published
2025-08-30
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Система моніторингу зчитування моргання з використанням магнітних властивостей ферофлюїду

The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy
Geochemistry and Geologic Mapping
article

Система моніторингу зчитування моргання з використанням магнітних властивостей ферофлюїду

article en

Abstract

The object of the study is an eye movement monitoring system based on a combination of a permanent magnet, ferrofluid and glasses with built-in inductive sensors. In the current conditions of development of wearable technologies and biomedical devices, such a system has the potential for application in medicine, in particular for monitoring eye movements in real time, which can be useful for diagnostics and rehabilitation. The problem considered in the study is to create a compact, comfortable and accurate system for non-contact monitoring of the frequency and nature of blinking. The main attention is paid to optimizing the design of the eyeglass frame with built-in coils, as well as the development of algorithms for collecting and processing induced signals, which allows for effective detection of eye movements without discomfort for the user. The essence of the results obtained is the development of a wearable system that uses ferrofluid applied to false eyelashes and magnetic coils built into a 3D-printed eyeglass frame. Experimental tests demonstrated the system’s ability to clearly distinguish between slow and fast blinking based on induced signals obtained using an Arduino Uno board with a reading frequency of 200 Hz. It was found that the amplitude of the signals during fast blinking is significantly higher, which ensures reliable tracking of eye movements in different modes. The results are explained by the innovative combination of a contactless magnetic sensor with a liquid form of ferrofluid, which ensures flexibility, comfort and invisibility of the system. Coils built into the frame allow for amplification of the induction signal, reducing the impact of noise and improving data quality. The use of a 3D model of the frame optimized for coil fixation ensures design reliability and repeatability of the results. The innovation of the approach lies in the combination of advanced materials and 3D printing technologies with traditional electronic solutions to create a compact and convenient eye movement monitoring device. The proposed system is a promising tool for further application in medical, rehabilitation and interface technologies, where precise control of blinking is critically important.

The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy
Vinnytsia National Technical University (UA)
Industry, innovation and infrastructure
Openalex Percentile: Top 68%
Geochemistry and Geologic Mapping
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.