Dataset for the article Effect of sulfide in a 0.2 M NaCl solution on copper and pre-oxidized copper in oxic conditions

This dataset supports the tables and figures in the article Effect of sulfide in a 0.2 M NaCl solution on copper and pre-oxidized copper in oxic conditions Effect of sulfide in a 0.2 M NaCl solution on copper and pre-oxidized copper in oxic conditions (https://doi.org/10.1016/j.surfin.2025.107387). The data set contains experimental data for copper and pre-oxidized copper samples exposed to chloride solution (0.2 M Cl–) with different sulfide concentrations (5·10–6 M SH– and 1·10–4 M SH–) at room temperature (22 ± 2 °C) and elevated temperature (60 °C). Corrosion potential was monitored over a period of 24 hours. After 24 h immersion, electrochemical impedance spectroscopy was performed to observe the properties of the surface film formed on the copper and the pre-oxidized copper. The dataset also includes images of pre-oxidized samples after 24 hours immersion in different solutions, original Raman spectra and Raman images, XPS data and images data from the scanning electron microscope and images of cross-section of samples. The dataset was also used for the model of corroding system (Figure 13)

Publication Details

Journal
DiRROS repository (University of Maribor)
Published
2025-08-11
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dataset for the article Effect of sulfide in a 0.2 M NaCl solution on copper and pre-oxidized copper in oxic conditions

DiRROS repository (University of Maribor)
Geochemistry and Geologic Mapping
article

Dataset for the article Effect of sulfide in a 0.2 M NaCl solution on copper and pre-oxidized copper in oxic conditions

article en

Abstract

This dataset supports the tables and figures in the article Effect of sulfide in a 0.2 M NaCl solution on copper and pre-oxidized copper in oxic conditions Effect of sulfide in a 0.2 M NaCl solution on copper and pre-oxidized copper in oxic conditions (https://doi.org/10.1016/j.surfin.2025.107387). The data set contains experimental data for copper and pre-oxidized copper samples exposed to chloride solution (0.2 M Cl–) with different sulfide concentrations (5·10–6 M SH– and 1·10–4 M SH–) at room temperature (22 ± 2 °C) and elevated temperature (60 °C). Corrosion potential was monitored over a period of 24 hours. After 24 h immersion, electrochemical impedance spectroscopy was performed to observe the properties of the surface film formed on the copper and the pre-oxidized copper. The dataset also includes images of pre-oxidized samples after 24 hours immersion in different solutions, original Raman spectra and Raman images, XPS data and images data from the scanning electron microscope and images of cross-section of samples. The dataset was also used for the model of corroding system (Figure 13)

DiRROS repository (University of Maribor)
Openalex Percentile: Top 68%
Geochemistry and Geologic Mapping
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.