Моделювання реології комерційних вогнезахисних фарб реактивного типу для сталевих конструкцій

Fire protection of steel load-bearing building structures by surface-treating them with reactive fire-retardant coating materials is a crucial factor in ensuring fire safety on national scale. Both, the quality and operational characteristics of such materials, which are the subject of this study, require continuous improvement to reduce the cost of fire protection, as it can constitute a large portion of the overall construction expenditure. The aim of this study was to determine optimal rheological parameters for commercial reactive fire-retardant coating materials that ensure that the material can be applied with the maximum wet coating thickness. To achieve this aim, the dynamic viscosity (η) was measured using Brookfield viscometer for a set of commercial reactive fire-retardant coating materials that provide fire resistance of at least R120 for steel load-bearing structures. The dependence of viscosity on shear rate (γ) in the range of (2.09–52.25) s–1 was modeled using the Casson equation. This allowed for the determination of the main rheological parameters of the studied materials – shear stress (τ, Pa), yield stress (τ0, Pa), and viscosity at high shear rates (η∞, Pa · s), which contribute to material’s applicability. With the use of the empirical and calculational data, the approximate viscosity of water-based intumescent coating materials necessary to produce defect-free layer of wet coating on studied surfaces was determined. It was measured by Brookfield viscometer with No. 7 spindle at rotational speeds (30–50) rpm at 20°С, and should preferably be: (30–15) Pa · s, (at 1 mm wet coating thickness); (50–25) Pa · s, (at 1.5 mm wet coating thickness), (80–50) Pa · s, (at 2.0 mm wet coating thickness). These levels of viscosity prevent sedimentation and sagging of the coating during material’s application and can serve as reference markers for optimization of industrially manufactured intumescent fire-retardant products. The obtained results can serve as practical recommendations for manufacturers seeking to improve the rheology of reactive fire-retardant materials in order to increase the wet coating thickness per layer.

Publication Details

Journal
The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy
Published
2025-08-29
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Моделювання реології комерційних вогнезахисних фарб реактивного типу для сталевих конструкцій

The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy
Geochemistry and Geologic Mapping
article

Моделювання реології комерційних вогнезахисних фарб реактивного типу для сталевих конструкцій

article en

Abstract

Fire protection of steel load-bearing building structures by surface-treating them with reactive fire-retardant coating materials is a crucial factor in ensuring fire safety on national scale. Both, the quality and operational characteristics of such materials, which are the subject of this study, require continuous improvement to reduce the cost of fire protection, as it can constitute a large portion of the overall construction expenditure. The aim of this study was to determine optimal rheological parameters for commercial reactive fire-retardant coating materials that ensure that the material can be applied with the maximum wet coating thickness. To achieve this aim, the dynamic viscosity (η) was measured using Brookfield viscometer for a set of commercial reactive fire-retardant coating materials that provide fire resistance of at least R120 for steel load-bearing structures. The dependence of viscosity on shear rate (γ) in the range of (2.09–52.25) s–1 was modeled using the Casson equation. This allowed for the determination of the main rheological parameters of the studied materials – shear stress (τ, Pa), yield stress (τ0, Pa), and viscosity at high shear rates (η∞, Pa · s), which contribute to material’s applicability. With the use of the empirical and calculational data, the approximate viscosity of water-based intumescent coating materials necessary to produce defect-free layer of wet coating on studied surfaces was determined. It was measured by Brookfield viscometer with No. 7 spindle at rotational speeds (30–50) rpm at 20°С, and should preferably be: (30–15) Pa · s, (at 1 mm wet coating thickness); (50–25) Pa · s, (at 1.5 mm wet coating thickness), (80–50) Pa · s, (at 2.0 mm wet coating thickness). These levels of viscosity prevent sedimentation and sagging of the coating during material’s application and can serve as reference markers for optimization of industrially manufactured intumescent fire-retardant products. The obtained results can serve as practical recommendations for manufacturers seeking to improve the rheology of reactive fire-retardant materials in order to increase the wet coating thickness per layer.

The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy
Sustainable cities and communities
Openalex Percentile: Top 72%
Geochemistry and Geologic Mapping
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.