On the Importance of Appropriate Current Probes for Double Pulse Tests and How to Select Them

Wide Band Gap power semiconductors require highly precise and low-intrusive measurement equipment to accurately measure their switching losses. The solutions developed for the characterization of Silicon power semiconductors have been proven to be too intrusive or to provide insufficient accuracy, leading to inadequate measurement results. In recent years, there have been several novel developments for sensors applied in Double Pulse Tests that aim to address key issues, warranting a comprehensive method to select a sensor that fits to the task of measuring fast transient signals. This paper proposes such a method, and presents a tool to quickly identify the estimated influence of sensors on the device behaviour. Moreover, it is advised that comparisons between sensors should not be based solely on the data sheet values (e.g. bandwidth and maximum current), as discrepancies in transmission behavior and definitions can result in the generation of misleading data, providing a false sense of security. In practice, the actual measurement behavior must be taken into account. This paper highlights these issues and develops a methodology which can minimize their impact on data quality.

Publication Details

Journal
Fraunhofer-Publica (Fraunhofer-Gesellschaft)
Published
2025-05-06
DOI
https://doi.org/10.30420/566541014
Primary Topic
Water Quality and Resources Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On the Importance of Appropriate Current Probes for Double Pulse Tests and How to Select Them

Fraunhofer-Publica (Fraunhofer-Gesellschaft)
Water Quality and Resources Studies
article

On the Importance of Appropriate Current Probes for Double Pulse Tests and How to Select Them

article en

Abstract

Wide Band Gap power semiconductors require highly precise and low-intrusive measurement equipment to accurately measure their switching losses. The solutions developed for the characterization of Silicon power semiconductors have been proven to be too intrusive or to provide insufficient accuracy, leading to inadequate measurement results. In recent years, there have been several novel developments for sensors applied in Double Pulse Tests that aim to address key issues, warranting a comprehensive method to select a sensor that fits to the task of measuring fast transient signals. This paper proposes such a method, and presents a tool to quickly identify the estimated influence of sensors on the device behaviour. Moreover, it is advised that comparisons between sensors should not be based solely on the data sheet values (e.g. bandwidth and maximum current), as discrepancies in transmission behavior and definitions can result in the generation of misleading data, providing a false sense of security. In practice, the actual measurement behavior must be taken into account. This paper highlights these issues and develops a methodology which can minimize their impact on data quality.

Fraunhofer-Publica (Fraunhofer-Gesellschaft)
Openalex Percentile: Top 55%
Water Quality and Resources Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.