Impact of Underground Obstructions in Double-Circuit Underground Power Lines: Ampacity and Induced Effect

This study presents a detailed analysis of the electrical and thermal interactions of underground power transmission lines, considering ampacity, induced voltages, and induced currents in the sheaths. Mathematical models estimate induced currents in different duct bank configurations (triangular, inverted triangular, flat, and vertical), accounting for geometric variations caused by underground obstructions such as pipelines and gas ducts. Two scenarios are investigated: a realistic case that incorporates the effects of obstructions on cable spacing and depth, and an idealized case that assumes uniform geometry. The study also examines the impact of sectionalized and continuous cross-bonding methods on system performance. The results, applied to a 220 kV double-circuit underground transmission line, demonstrate how real-world conditions directly influence the electrical and thermal characteristics of the system. Finally, engineering recommendations are provided, taking into account the induced currents associated with core temperature rise.

Institutions

Publication Details

Journal
IEEE Transactions on Industry Applications
Published
2025-08-15
DOI
https://doi.org/10.1109/tia.2025.3599464
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Underground Obstructions in Double-Circuit Underground Power Lines: Ampacity and Induced Effect

IEEE Transactions on Industry Applications
Geochemistry and Geologic Mapping
article

Impact of Underground Obstructions in Double-Circuit Underground Power Lines: Ampacity and Induced Effect

article en

Abstract

This study presents a detailed analysis of the electrical and thermal interactions of underground power transmission lines, considering ampacity, induced voltages, and induced currents in the sheaths. Mathematical models estimate induced currents in different duct bank configurations (triangular, inverted triangular, flat, and vertical), accounting for geometric variations caused by underground obstructions such as pipelines and gas ducts. Two scenarios are investigated: a realistic case that incorporates the effects of obstructions on cable spacing and depth, and an idealized case that assumes uniform geometry. The study also examines the impact of sectionalized and continuous cross-bonding methods on system performance. The results, applied to a 220 kV double-circuit underground transmission line, demonstrate how real-world conditions directly influence the electrical and thermal characteristics of the system. Finally, engineering recommendations are provided, taking into account the induced currents associated with core temperature rise.

IEEE Transactions on Industry ApplicationsVol. 62(2)
Universidade Federal de Lavras (BR), Universidade Estadual de Campinas (UNICAMP) (BR), Universidade Estadual Paulista (Unesp) (BR)
Sustainable cities and communities
Openalex Percentile: Top 72%
Geochemistry and Geologic Mapping
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Impact of Underground Obstructions in Double-Circuit Underground Power Lines: Ampacity and Induced Effect · IEEE Transactions on Industry Applications (2025) | TGRS Research Map | TGRS