REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY METHOD FOR SIMULTANEOUS ESTIMATION OF BACLOFEN AND TRAMADOL IN BULK AND PHARMACEUTICAL DOSAGE FORM

The present research work describes a novel, simple, accurate, sensitive, rapid reversed-phase liquid chromatographic method for simultaneous estimation of Baclofen and Tramadol in bulk & pharmaceutical formulations. The chromatographic separation was achieved on WATERS HPLC with PDA detector and column Inertsil ODS, phosphate buffer and methanol as mobile phase at a flow rate of 1.0ml/min. The detection was carried out at 256 nm. The retention time of Baclofen and Tramadol was found to be 2.5 and 3.9. %Recoveries obtained for Baclofen and Tramadol were 99.85% & 100.5%.The %RSD below 2.0 shows the high precision of proposed method. The method was validated for precision, Recovery, Specify Detection & Quantification limits in accordance with ICH guidelines. KEYWORDS: Baclofen, Tramadol, RP-HPLC, Validation

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-08-17
DOI
https://doi.org/10.5281/zenodo.16890301
Primary Topic
Diverse Scientific and Economic Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY METHOD FOR SIMULTANEOUS ESTIMATION OF BACLOFEN AND TRAMADOL IN BULK AND PHARMACEUTICAL DOSAGE FORM

Zenodo (CERN European Organization for Nuclear Research)
Diverse Scientific and Economic Studies
article

REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY METHOD FOR SIMULTANEOUS ESTIMATION OF BACLOFEN AND TRAMADOL IN BULK AND PHARMACEUTICAL DOSAGE FORM

article en

Abstract

The present research work describes a novel, simple, accurate, sensitive, rapid reversed-phase liquid chromatographic method for simultaneous estimation of Baclofen and Tramadol in bulk & pharmaceutical formulations. The chromatographic separation was achieved on WATERS HPLC with PDA detector and column Inertsil ODS, phosphate buffer and methanol as mobile phase at a flow rate of 1.0ml/min. The detection was carried out at 256 nm. The retention time of Baclofen and Tramadol was found to be 2.5 and 3.9. %Recoveries obtained for Baclofen and Tramadol were 99.85% & 100.5%.The %RSD below 2.0 shows the high precision of proposed method. The method was validated for precision, Recovery, Specify Detection & Quantification limits in accordance with ICH guidelines. KEYWORDS: Baclofen, Tramadol, RP-HPLC, Validation

Zenodo (CERN European Organization for Nuclear Research)
Clean water and sanitation
Openalex Percentile: Top 37%
Diverse Scientific and Economic Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.