Impact of scapula anatomical landmark positioning on scapular orientation using CT-based 3-dimensional models : an intraobserver repeatability and interobserver reproducibility study

<b> Hypothesis: </b> The primary objective of this study was to assess intraobserver repeatability and interobserver reproducibility of the 3-dimensional (3D) coordinates of a set of scapula anatomical landmarks obtained by manual positioning on conventional supine computed tomography (CT) scan-based scapula surface models. The secondary objective was to assess intraobserver repeatability and interobserver reproducibility of the resulting 3D scapular orientation. It was hypothesized that the 3D scapular orientation reliability would be better or similar than established reliability of intraoperative baseplate positioning (ie, version and inclination) in reverse total shoulder arthroplasty. <b> Methods: </b> Three anatomical landmarks, ie, acromial angle, inferior angle, and trigonum spinae, were manually positioned on 81 scapula surface models using updated landmark definitions. These models were obtained by the segmentation of CT scan images acquired from patients undergoing elective reverse total shoulder arthroplasty procedures at the Department of Surgery at Geneva University Hospitals between May 2022 and December 2023. This procedure was repeated 3 times per scapula by 3 independent observers. A set of parameters corresponding to the 3D landmark coordinates (expressed in an average scapula coordinate system) and the 3D scapular orientation (expressed as 3 angles related to the retraction/protraction, lateral/medial rotation, and internal/external rotation) were computed. Intraobserver repeatability and interobserver reproducibility were assessed for each of these parameters using an intraclass correlation coefficient (ICC) as a relative reliability metric. Standard error of measurement (SEM) was also reported as an absolute reliability metric. <b> Results: </b> Intraobserver ICC and interobserver ICC ranged from poor to moderate for acromial angle, poor to excellent for inferior angle, and poor to excellent for trigonum spinae. However, low SEM, ranging from 0.4 mm to 2.4 mm for intraobserver repeatability and from 0.2 mm to 1.8 mm for interobserver reproducibility, was obtained for every coordinate of each anatomical landmark. This results in poor to moderate intraobserver ICC and interobserver ICC for scapula angular orientation. Again, low SEM, ranging from 0.4° to 0.8° for intraobserver repeatability and 0.4° to 0.6° for interobserver reproducibility, was obtained, arguing for reliable measurements. <b> Discussion: </b> This study demonstrates that manual positioning of the 3 scapula anatomical landmarks recommended by the International Society of Biomechanics can be performed in a reliable manner across measures and observers on surface bone models obtained from CT scan images. However, a clear and standardized definition of these landmarks is needed to ensure consistency across measurements.

Publication Details

Journal
Archive ouverte UNIGE (University of Geneva)
Published
2025-01-01
Primary Topic
Pregnancy and preeclampsia studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of scapula anatomical landmark positioning on scapular orientation using CT-based 3-dimensional models : an intraobserver repeatability and interobserver reproducibility study

Archive ouverte UNIGE (University of Geneva)
Pregnancy and preeclampsia studies
article

Impact of scapula anatomical landmark positioning on scapular orientation using CT-based 3-dimensional models : an intraobserver repeatability and interobserver reproducibility study

article en

Abstract

<b> Hypothesis: </b> The primary objective of this study was to assess intraobserver repeatability and interobserver reproducibility of the 3-dimensional (3D) coordinates of a set of scapula anatomical landmarks obtained by manual positioning on conventional supine computed tomography (CT) scan-based scapula surface models. The secondary objective was to assess intraobserver repeatability and interobserver reproducibility of the resulting 3D scapular orientation. It was hypothesized that the 3D scapular orientation reliability would be better or similar than established reliability of intraoperative baseplate positioning (ie, version and inclination) in reverse total shoulder arthroplasty. <b> Methods: </b> Three anatomical landmarks, ie, acromial angle, inferior angle, and trigonum spinae, were manually positioned on 81 scapula surface models using updated landmark definitions. These models were obtained by the segmentation of CT scan images acquired from patients undergoing elective reverse total shoulder arthroplasty procedures at the Department of Surgery at Geneva University Hospitals between May 2022 and December 2023. This procedure was repeated 3 times per scapula by 3 independent observers. A set of parameters corresponding to the 3D landmark coordinates (expressed in an average scapula coordinate system) and the 3D scapular orientation (expressed as 3 angles related to the retraction/protraction, lateral/medial rotation, and internal/external rotation) were computed. Intraobserver repeatability and interobserver reproducibility were assessed for each of these parameters using an intraclass correlation coefficient (ICC) as a relative reliability metric. Standard error of measurement (SEM) was also reported as an absolute reliability metric. <b> Results: </b> Intraobserver ICC and interobserver ICC ranged from poor to moderate for acromial angle, poor to excellent for inferior angle, and poor to excellent for trigonum spinae. However, low SEM, ranging from 0.4 mm to 2.4 mm for intraobserver repeatability and from 0.2 mm to 1.8 mm for interobserver reproducibility, was obtained for every coordinate of each anatomical landmark. This results in poor to moderate intraobserver ICC and interobserver ICC for scapula angular orientation. Again, low SEM, ranging from 0.4° to 0.8° for intraobserver repeatability and 0.4° to 0.6° for interobserver reproducibility, was obtained, arguing for reliable measurements. <b> Discussion: </b> This study demonstrates that manual positioning of the 3 scapula anatomical landmarks recommended by the International Society of Biomechanics can be performed in a reliable manner across measures and observers on surface bone models obtained from CT scan images. However, a clear and standardized definition of these landmarks is needed to ensure consistency across measurements.

Archive ouverte UNIGE (University of Geneva)
No poverty
Openalex Percentile: Top 38%
Pregnancy and preeclampsia studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.