Molecularly imprinted nanoparticle-based polymer (acrylamide-N-vinyl imidazole)/nafion film modified screen-printed electrode system for rapid determination of hemoglobin

In medical diagnostics, variations in hemoglobin levels can reveal a variety of prevalent health conditions. Abnormal hemoglobin is known to be connected with diseases like anemia, diabetes, hematemesis, hematuria, and hemoglobinuria. Consequently, there is a significant demand for advanced detection technologies and precise methodologies to accurately track and assess hemoglobin levels. This study demonstrates the potential of a novel molecularly imprinted nanoparticle-based sensor system to rapidly analyze hemoglobin levels without the need for a laboratory environment. Hemoglobin imprinted-poly(acrylamide-co-vinyl imidazole) [Hb-imp-p(AAm-co-VIM)] nanoparticles with high affinity and selectivity for hemoglobin were synthesized and loaded onto the surface of a screen-printed carbon electrode (SPCE) with a nafion nanofilm. Nafion has selective ion exchange properties and allows for the enhancement of the electrochemical signal. An increase in signal was observed in the presence of 0.5% Nafion. The Hb-imp-p(AAm-co-VIM)/Nafion-SPCE system was employed as the sensor surface for the detection of hemoglobin levels in blood. The Hb-imp-p(AAm-co-VIM)/Nafion-SPCE system was characterized by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) measurements. The linear working range for hemoglobin was observed to be 0.73–15.54 μM (R2: 0.9934), with a calculated limit of detection (LoD) value of 0.24 μM (3.3 S/N). The sensor system exhibited high efficiency at the biological pH value of 7.4. Furthermore, percent recovery values for hemoglobin in blood samples were observed to be between 90.34% and 103.68%. To determine the selectivity of the Hb-imp-p(AAm-co-VIM)/Nafion-SPCE electrode system, the current values of the system were investigated in the presence of ascorbic acid, cysteine, glucose, and IgG. The system exhibited high selectivity. Based on the data obtained, it is evident that the Hb-imp-p(AAm-co-VIM)/Nafion-SPCE system can detect hemoglobin in biological environments and has the potential for use in disease monitoring systems.

Publication Details

Journal
Sabanci University
Published
2024-12-01
Primary Topic
Diverse Scientific and Economic Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Molecularly imprinted nanoparticle-based polymer (acrylamide-N-vinyl imidazole)/nafion film modified screen-printed electrode system for rapid determination of hemoglobin

Sabanci University
Diverse Scientific and Economic Studies
article

Molecularly imprinted nanoparticle-based polymer (acrylamide-N-vinyl imidazole)/nafion film modified screen-printed electrode system for rapid determination of hemoglobin

article en

Abstract

In medical diagnostics, variations in hemoglobin levels can reveal a variety of prevalent health conditions. Abnormal hemoglobin is known to be connected with diseases like anemia, diabetes, hematemesis, hematuria, and hemoglobinuria. Consequently, there is a significant demand for advanced detection technologies and precise methodologies to accurately track and assess hemoglobin levels. This study demonstrates the potential of a novel molecularly imprinted nanoparticle-based sensor system to rapidly analyze hemoglobin levels without the need for a laboratory environment. Hemoglobin imprinted-poly(acrylamide-co-vinyl imidazole) [Hb-imp-p(AAm-co-VIM)] nanoparticles with high affinity and selectivity for hemoglobin were synthesized and loaded onto the surface of a screen-printed carbon electrode (SPCE) with a nafion nanofilm. Nafion has selective ion exchange properties and allows for the enhancement of the electrochemical signal. An increase in signal was observed in the presence of 0.5% Nafion. The Hb-imp-p(AAm-co-VIM)/Nafion-SPCE system was employed as the sensor surface for the detection of hemoglobin levels in blood. The Hb-imp-p(AAm-co-VIM)/Nafion-SPCE system was characterized by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) measurements. The linear working range for hemoglobin was observed to be 0.73–15.54 μM (R2: 0.9934), with a calculated limit of detection (LoD) value of 0.24 μM (3.3 S/N). The sensor system exhibited high efficiency at the biological pH value of 7.4. Furthermore, percent recovery values for hemoglobin in blood samples were observed to be between 90.34% and 103.68%. To determine the selectivity of the Hb-imp-p(AAm-co-VIM)/Nafion-SPCE electrode system, the current values of the system were investigated in the presence of ascorbic acid, cysteine, glucose, and IgG. The system exhibited high selectivity. Based on the data obtained, it is evident that the Hb-imp-p(AAm-co-VIM)/Nafion-SPCE system can detect hemoglobin in biological environments and has the potential for use in disease monitoring systems.

Sabanci University
Openalex Percentile: Top 27%
Diverse Scientific and Economic Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.