Impact of ultrasound settings on lung vertical artefacts: an observational study in mechanically ventilated patients

The number of vertical artefacts (VAs) in lung ultrasound (LUS) impacts patients' clinical management. This study aimed to demonstrate the influence of ultrasound settings on the number of VAs in patients under invasive mechanical ventilation (IMV). Methods: Patients under IMV were recruited for LUS, including three breathing cycles with a motionless curvilinear probe on the thoracic region with the most VAs. Three experts in LUS were asked about the number of VAs at random, and blinded after altering the settings for a total of 20 test recordings per patient. The correlation between expert classifications was tested after grading the classifications. The number of VAs across clinicians was compared between baseline recordings and test condition recordings to determine statistical differences. Results: 29 patients were enrolled with a median Sequential Organ Failure Assessment score of 6 (interquartile range (IQR) 3). IMV was mainly due to stroke (n=10) and pneumonia (n=6). LUS was made between days 1 and 6 (IQR). Baseline recordings showed a median of 2±2 VAs in inspiration and a median of 1±2 in expiration from 3636 expert classifications, with a strong agreement among patients. A probe frequency of 8 MHz, artefact filtering, speckle reduction, and frame average reduced the median VA number by one. A power of -20 dB and a dynamic range of 32 dB abolished the VAs. A gain above 90% increased the median number of VAs by one. Conclusion: In this in vivo study, the LUS settings influenced the VA number in IMV patients, after controlling for physiological and operator confounders.

Publication Details

Journal
Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT)
Published
2025-01-01
Primary Topic
Theoretical and Computational Physics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of ultrasound settings on lung vertical artefacts: an observational study in mechanically ventilated patients

Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT)
Theoretical and Computational Physics
article

Impact of ultrasound settings on lung vertical artefacts: an observational study in mechanically ventilated patients

article en

Abstract

The number of vertical artefacts (VAs) in lung ultrasound (LUS) impacts patients' clinical management. This study aimed to demonstrate the influence of ultrasound settings on the number of VAs in patients under invasive mechanical ventilation (IMV). Methods: Patients under IMV were recruited for LUS, including three breathing cycles with a motionless curvilinear probe on the thoracic region with the most VAs. Three experts in LUS were asked about the number of VAs at random, and blinded after altering the settings for a total of 20 test recordings per patient. The correlation between expert classifications was tested after grading the classifications. The number of VAs across clinicians was compared between baseline recordings and test condition recordings to determine statistical differences. Results: 29 patients were enrolled with a median Sequential Organ Failure Assessment score of 6 (interquartile range (IQR) 3). IMV was mainly due to stroke (n=10) and pneumonia (n=6). LUS was made between days 1 and 6 (IQR). Baseline recordings showed a median of 2±2 VAs in inspiration and a median of 1±2 in expiration from 3636 expert classifications, with a strong agreement among patients. A probe frequency of 8 MHz, artefact filtering, speckle reduction, and frame average reduced the median VA number by one. A power of -20 dB and a dynamic range of 32 dB abolished the VAs. A gain above 90% increased the median number of VAs by one. Conclusion: In this in vivo study, the LUS settings influenced the VA number in IMV patients, after controlling for physiological and operator confounders.

Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT)
Good health and well-being
Openalex Percentile: Top 61%
Theoretical and Computational Physics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Impact of ultrasound settings on lung vertical artefacts: an observational study in mechanically ventilated patients · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) (2025) | TGRS Research Map | TGRS