Use of the Medtronic Microvascular Plug 7Q for transcatheter closure of large patent ductus arteriosus in infants weighing less than 2.5 kg

<p><strong>Background:</strong> The sole Food and Drug Administration-approved device for transcatheter closure of the patent arterial duct in premature infants is indicated for patent ductus arteriosus (PDAs) ≤ 4 mm in diameter. We report a two-center experience with transcatheter closure of large PDAs (>4 mm) in infants weighing <2.5 kg using the Microvascular Plug 7Q (MVP-7Q) device.</p>\n<p><strong>Methods:</strong> This is a retrospective review of departmental databases and medical charts to define patient cohort and report demographic, procedural, and follow-up data.</p>\n<p><strong>Results:</strong> Twenty-two patients (12 male) with a median gestational age and birthweight of 25.5 weeks (interquartile range [IQR] = 24-28) and 800 g (572-1075), respectively, underwent attempted PDA occlusion with the MVP-7Q using a transvenous approach. The median age and weight at the time of PDA occlusion was 32 days (IQR = 24-28) and 1100 g (IQR = 960-1700), respectively. The median PDA length was 12 mm (IQR = 11-12.65). The median PDA diameters at the aortic and pulmonary ends were 5.1 (IQR = 4.9-5.5) and 4.8 mm (IQR = 4.6-5.3), respectively. Successful device occlusion was achieved in 20 patients (91%). There were two failed attempts: One due to inappropriate sizing, and the other secondary to left pulmonary artery stenosis. There were no procedural complications and no residual shunting on follow-up.</p>\n<p><strong>Conclusions:</strong> The MVP-7Q is safe and effective for transcatheter closure of large (>4 mm) PDAs in infants <2.5 kg. The lack of retention disks may help with avoiding impingement on surrounding vessels.</p>

Publication Details

Journal
Figshare
Published
2024-10-04
Primary Topic
Theoretical and Computational Physics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Use of the Medtronic Microvascular Plug 7Q for transcatheter closure of large patent ductus arteriosus in infants weighing less than 2.5 kg

Figshare
Theoretical and Computational Physics
article

Use of the Medtronic Microvascular Plug 7Q for transcatheter closure of large patent ductus arteriosus in infants weighing less than 2.5 kg

article en

Abstract

<p><strong>Background:</strong> The sole Food and Drug Administration-approved device for transcatheter closure of the patent arterial duct in premature infants is indicated for patent ductus arteriosus (PDAs) ≤ 4 mm in diameter. We report a two-center experience with transcatheter closure of large PDAs (>4 mm) in infants weighing <2.5 kg using the Microvascular Plug 7Q (MVP-7Q) device.</p>\n<p><strong>Methods:</strong> This is a retrospective review of departmental databases and medical charts to define patient cohort and report demographic, procedural, and follow-up data.</p>\n<p><strong>Results:</strong> Twenty-two patients (12 male) with a median gestational age and birthweight of 25.5 weeks (interquartile range [IQR] = 24-28) and 800 g (572-1075), respectively, underwent attempted PDA occlusion with the MVP-7Q using a transvenous approach. The median age and weight at the time of PDA occlusion was 32 days (IQR = 24-28) and 1100 g (IQR = 960-1700), respectively. The median PDA length was 12 mm (IQR = 11-12.65). The median PDA diameters at the aortic and pulmonary ends were 5.1 (IQR = 4.9-5.5) and 4.8 mm (IQR = 4.6-5.3), respectively. Successful device occlusion was achieved in 20 patients (91%). There were two failed attempts: One due to inappropriate sizing, and the other secondary to left pulmonary artery stenosis. There were no procedural complications and no residual shunting on follow-up.</p>\n<p><strong>Conclusions:</strong> The MVP-7Q is safe and effective for transcatheter closure of large (>4 mm) PDAs in infants <2.5 kg. The lack of retention disks may help with avoiding impingement on surrounding vessels.</p>

Figshare
Good health and well-being
Openalex Percentile: Top 58%
Theoretical and Computational Physics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Use of the Medtronic Microvascular Plug 7Q for transcatheter closure of large patent ductus arteriosus in infants weighing less than 2.5 kg · Figshare (2024) | TGRS Research Map | TGRS