First 2D electron density measurements using multi-delay coherence imaging spectroscopy in the MAST-U Super-X divertor

2D profiles of electron density and neutral temperature are inferred from multi-delay coherence imaging spectroscopy data of divertor plasmas using a non-linear inversion technique. The inference is based on imaging the spectral line-broadening of Balmer lines and can differentiate between the Doppler and Stark broadening components by measuring the fringe contrast at multiple interferometric delays simultaneously. The model has been applied to images generated from simulated density profiles to evaluate its performance. Typical mean absolute errors of 30% are achieved, which are consistent with Monte Carlo uncertainty propagation accounting for noise, uncertainties in the calibrations, and in the model inputs. The analysis has been tested on experimental data from the MAST-U Super-X divertor, where it infers typical electron densities of 2-3 10 19 m-3 and neutral temperatures of 0-2 eV during beam-heated L-mode discharges. The results are shown to be in reasonable agreement with the other available diagnostics.

Publication Details

Journal
DIFFER: Publications
Published
2025-01-01
Primary Topic
Diverse Scientific and Economic Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

First 2D electron density measurements using multi-delay coherence imaging spectroscopy in the MAST-U Super-X divertor

DIFFER: Publications
Diverse Scientific and Economic Studies
article

First 2D electron density measurements using multi-delay coherence imaging spectroscopy in the MAST-U Super-X divertor

article en

Abstract

2D profiles of electron density and neutral temperature are inferred from multi-delay coherence imaging spectroscopy data of divertor plasmas using a non-linear inversion technique. The inference is based on imaging the spectral line-broadening of Balmer lines and can differentiate between the Doppler and Stark broadening components by measuring the fringe contrast at multiple interferometric delays simultaneously. The model has been applied to images generated from simulated density profiles to evaluate its performance. Typical mean absolute errors of 30% are achieved, which are consistent with Monte Carlo uncertainty propagation accounting for noise, uncertainties in the calibrations, and in the model inputs. The analysis has been tested on experimental data from the MAST-U Super-X divertor, where it infers typical electron densities of 2-3 10 19 m-3 and neutral temperatures of 0-2 eV during beam-heated L-mode discharges. The results are shown to be in reasonable agreement with the other available diagnostics.

DIFFER: Publications
Openalex Percentile: Top 37%
Diverse Scientific and Economic Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.