Correction of z-motion artefacts to allow population imaging of synaptic activity in behaving mice

Key points: Motion artefacts associated with motor behaviour are an inevitable problem of multiphoton imaging in awake behaving animals, particularly when imaging synapses. Correction of axial motion artefacts usually requires volumetric imaging resulting in slower rates of acquisition. We describe a method to correct z-motion artefacts that is easy to implement and allows population imaging of synaptic activity while scanning a single plane in a standard multiphoton microscope. The method uses a reference volume acquired in two colour channels – an activity reporter and an anatomical marker of blood vessels. The procedure estimates the z-displacement in every frame and applies an intensity correction in which the z intensity profile for each synapse is modelled as a Moffat function. We demonstrate that the method allows synaptic calcium signals to be collected from populations of synaptic boutons in mouse primary visual cortex during locomotion. Abstract: Functional imaging of head-fixed, behaving mice using two-photon imaging of fluorescent activity reporters has become a powerful tool for studying the function of the brain. Motion artefacts are an inevitable problem during such experiments and are routinely corrected for in x and y dimensions. However, axial (z) shifts of several microns can also occur, leading to intensity fluctuations in structures such as synapses that are small compared to the axial point-spread function of the microscope. Here we present a simple strategy to correct z-motion artefacts arising over the course of a time-series experiment in a single optical plane. Displacement in z was calculated using dye-filled blood vessels as an anatomical marker, providing high contrast images and accuracy to within ∼0.1 µm. The axial profiles of ROIs corresponding to synapses were described using a Moffat function and this ‘ROI-spread function’ used to correct activity traces on an ROI-by-ROI basis. We demonstrate the accuracy and utility of the procedures in simulation experiments using fluorescent beads and then apply them to correcting measurements of synaptic activity in populations of vasoactive-intestinal peptide (VIP) interneurons expressing the synaptic reporter SyGCaMP6f. Correction of z-motion artefacts had a substantial impact on the apparent correlation between synaptic activity and running speed, demonstrating the importance of correcting these when performing imaging experiments in awake mice.

Publication Details

Journal
Figshare
Published
2025-03-28
Citations
2
Primary Topic
Prenatal Screening and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Correction of z-motion artefacts to allow population imaging of synaptic activity in behaving mice

2 citations
Figshare
Prenatal Screening and Diagnostics
article

Correction of z-motion artefacts to allow population imaging of synaptic activity in behaving mice

article en
2 citations

Abstract

Key points: Motion artefacts associated with motor behaviour are an inevitable problem of multiphoton imaging in awake behaving animals, particularly when imaging synapses. Correction of axial motion artefacts usually requires volumetric imaging resulting in slower rates of acquisition. We describe a method to correct z-motion artefacts that is easy to implement and allows population imaging of synaptic activity while scanning a single plane in a standard multiphoton microscope. The method uses a reference volume acquired in two colour channels – an activity reporter and an anatomical marker of blood vessels. The procedure estimates the z-displacement in every frame and applies an intensity correction in which the z intensity profile for each synapse is modelled as a Moffat function. We demonstrate that the method allows synaptic calcium signals to be collected from populations of synaptic boutons in mouse primary visual cortex during locomotion. Abstract: Functional imaging of head-fixed, behaving mice using two-photon imaging of fluorescent activity reporters has become a powerful tool for studying the function of the brain. Motion artefacts are an inevitable problem during such experiments and are routinely corrected for in x and y dimensions. However, axial (z) shifts of several microns can also occur, leading to intensity fluctuations in structures such as synapses that are small compared to the axial point-spread function of the microscope. Here we present a simple strategy to correct z-motion artefacts arising over the course of a time-series experiment in a single optical plane. Displacement in z was calculated using dye-filled blood vessels as an anatomical marker, providing high contrast images and accuracy to within ∼0.1 µm. The axial profiles of ROIs corresponding to synapses were described using a Moffat function and this ‘ROI-spread function’ used to correct activity traces on an ROI-by-ROI basis. We demonstrate the accuracy and utility of the procedures in simulation experiments using fluorescent beads and then apply them to correcting measurements of synaptic activity in populations of vasoactive-intestinal peptide (VIP) interneurons expressing the synaptic reporter SyGCaMP6f. Correction of z-motion artefacts had a substantial impact on the apparent correlation between synaptic activity and running speed, demonstrating the importance of correcting these when performing imaging experiments in awake mice.

Figshare
Openalex Percentile: Top 36%
Prenatal Screening and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Correction of z-motion artefacts to allow population imaging of synaptic activity in behaving mice · Figshare (2025) | TGRS Research Map | TGRS