Performance of the FreeStyle Libre Flash glucose monitoring system during an oral glucose tolerance test and exercise in healthy adolescents

<p dir="ltr">This study’s aim was to assess FreeStyle Libre Flash glucose monitoring (FGM) performance during an oral glucose tolerance test (OGTT) and treadmill exercise in healthy adolescents. This should advance the feasibility and utility of user-friendly technologies for metabolic assessments in adolescents. Seventeen healthy adolescents (nine girls aged 12.8 ± 0.9 years) performed an OGTT and submaximal and maximal treadmill exercise tests in a laboratory setting. The scanned interstitial fluid glucose concentration ([ISFG]) obtained by FGM was compared against finger-prick capillary plasma glucose concentration ([CPG]) at 0 (pre-OGTT), −15, −30, −60, −120 min post-OGTT, pre-, mid-, post- submaximal exercise, and pre- and post- maximal exercise. Overall mean absolute relative difference (MARD) was 13.1 ± 8.5%, and 68% (<i>n</i> = 113) of the paired glucose data met the ISO 15197:2013 criteria. For clinical accuracy, 84% and 16% of FGM readings were within zones A and B in the Consensus Error Grid (CEG), respectively, which met the ISO 15197:2013 criteria of having at least 99% of results within these zones. Scanned [ISFG] were statistically lower than [CPG] at 15 (−1.16 mmol∙L<sup>−1</sup>, p < 0.001) and 30 min (−0.74 mmol∙L<sup>−1</sup>, <i>p</i> = 0.041) post-OGTT. Yet, post-OGTT glycaemic responses assessed by total and incremental areas under the curve (AUCs) were not significantly different, with trivial to small effect sizes (<i>p</i> ≥ 0.084, d = 0.14–0.45). Further, [ISFGs] were not different from [CPGs] during submaximal and maximal exercise tests (interaction <i>p</i> ≥ 0.614). FGM can be a feasible alternative to reflect postprandial glycaemia (AUCs) in healthy adolescents who may not endure repeated finger pricks.

Publication Details

Journal
Figshare
Published
2025-03-11
Primary Topic
Glass properties and applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance of the FreeStyle Libre Flash glucose monitoring system during an oral glucose tolerance test and exercise in healthy adolescents

Figshare
Glass properties and applications
article

Performance of the FreeStyle Libre Flash glucose monitoring system during an oral glucose tolerance test and exercise in healthy adolescents

article en

Abstract

<p dir="ltr">This study’s aim was to assess FreeStyle Libre Flash glucose monitoring (FGM) performance during an oral glucose tolerance test (OGTT) and treadmill exercise in healthy adolescents. This should advance the feasibility and utility of user-friendly technologies for metabolic assessments in adolescents. Seventeen healthy adolescents (nine girls aged 12.8 ± 0.9 years) performed an OGTT and submaximal and maximal treadmill exercise tests in a laboratory setting. The scanned interstitial fluid glucose concentration ([ISFG]) obtained by FGM was compared against finger-prick capillary plasma glucose concentration ([CPG]) at 0 (pre-OGTT), −15, −30, −60, −120 min post-OGTT, pre-, mid-, post- submaximal exercise, and pre- and post- maximal exercise. Overall mean absolute relative difference (MARD) was 13.1 ± 8.5%, and 68% (<i>n</i> = 113) of the paired glucose data met the ISO 15197:2013 criteria. For clinical accuracy, 84% and 16% of FGM readings were within zones A and B in the Consensus Error Grid (CEG), respectively, which met the ISO 15197:2013 criteria of having at least 99% of results within these zones. Scanned [ISFG] were statistically lower than [CPG] at 15 (−1.16 mmol∙L<sup>−1</sup>, p < 0.001) and 30 min (−0.74 mmol∙L<sup>−1</sup>, <i>p</i> = 0.041) post-OGTT. Yet, post-OGTT glycaemic responses assessed by total and incremental areas under the curve (AUCs) were not significantly different, with trivial to small effect sizes (<i>p</i> ≥ 0.084, d = 0.14–0.45). Further, [ISFGs] were not different from [CPGs] during submaximal and maximal exercise tests (interaction <i>p</i> ≥ 0.614). FGM can be a feasible alternative to reflect postprandial glycaemia (AUCs) in healthy adolescents who may not endure repeated finger pricks.

Figshare
Quality Education
Openalex Percentile: Top 56%
Glass properties and applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.