Heart Rate Estimation from PPG Signals at Large Proximal Arteries

Photoplethysmography (PPG) is a noninvasive optical method widely used for cardiovascular monitoring. Its accuracy in heart rate (HR) estimation is challenged by different noise types, especially motion artifacts during physical activity. This study investigates HR estimation from PPG signals recorded at the carotid and brachial arteries before and after ercise, using red (660 nm) and near-infrared (880 nm) light sensors. A pulse-to-pulse time-domain method and a spectral analysis approach were employed. ECG was used as the gold standard. The results demonstrate that the red-light PPG sensor provides superior accuracy, achieving a root mean square error (RMSE) of 2.25 bpm, while spectral analysis exhibited significantly larger errors. When evaluated for heartbeat detection, the proposed approach achieved a sensitivity of 98.45%, a positive predictive value of 99.51%, and a detection error rate of 2.03%, highlighting its robustness in HR estimation. These findings underscore the potential of PPG sensors at large proximal arteries for accurate cardiovascular monitoring and multiparameter assessment, even in the presence of occasional motion artifacts.

Publication Details

Journal
VinaR (Institute of Nuclear Sciences "Vinča")
Published
2025-01-01
Primary Topic
Laser-Plasma Interactions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Heart Rate Estimation from PPG Signals at Large Proximal Arteries

VinaR (Institute of Nuclear Sciences "Vinča")
Laser-Plasma Interactions and Diagnostics
article

Heart Rate Estimation from PPG Signals at Large Proximal Arteries

article en

Abstract

Photoplethysmography (PPG) is a noninvasive optical method widely used for cardiovascular monitoring. Its accuracy in heart rate (HR) estimation is challenged by different noise types, especially motion artifacts during physical activity. This study investigates HR estimation from PPG signals recorded at the carotid and brachial arteries before and after ercise, using red (660 nm) and near-infrared (880 nm) light sensors. A pulse-to-pulse time-domain method and a spectral analysis approach were employed. ECG was used as the gold standard. The results demonstrate that the red-light PPG sensor provides superior accuracy, achieving a root mean square error (RMSE) of 2.25 bpm, while spectral analysis exhibited significantly larger errors. When evaluated for heartbeat detection, the proposed approach achieved a sensitivity of 98.45%, a positive predictive value of 99.51%, and a detection error rate of 2.03%, highlighting its robustness in HR estimation. These findings underscore the potential of PPG sensors at large proximal arteries for accurate cardiovascular monitoring and multiparameter assessment, even in the presence of occasional motion artifacts.

VinaR (Institute of Nuclear Sciences "Vinča")
Good health and well-being
Openalex Percentile: Top 31%
Laser-Plasma Interactions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Heart Rate Estimation from PPG Signals at Large Proximal Arteries · VinaR (Institute of Nuclear Sciences "Vinča") (2025) | TGRS Research Map | TGRS