Experimental and theoretical study of used GFRP I-profile composite columns

Glass Fiber Reinforced Polymer (GFRP) is a promising alternative to steel due to its high strength, lightweight properties, corrosion resistance, and low maintenance requirements. This study examines the effect of internal GFRP I-sections on the axial load capacity and fire resistance of reinforced concrete (RC) columns. The experimental program consisted of two groups: the first group, conventional RC columns, with one exposed to 500°C for 90 minutes and the other unheated, and the second group, GFRP I-section reinforced columns, similarly tested under fire and control conditions. Results show that GFRP-reinforced columns exhibited a 17% higher axial capacity than conventional RC columns. However, fire exposure reduced the axial strength of GFRP-reinforced columns by 39% compared to unheated specimens and by 14% compared to conventional RC columns. Theoretical axial load capacities were calculated using design codes, and finite element analysis (FEA) validated the experimental results. Additional parameters, including concrete strength, steel yield strength, reinforcement ratio, and GFRP section properties, were analyzed. The strong correlation between experimental, theoretical, and numerical results provides a foundation for developing practical design guidelines for GFRP-reinforced composite columns.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-03-01
Primary Topic
Magnetic confinement fusion research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental and theoretical study of used GFRP I-profile composite columns

SHILAP Revista de lepidopterología
Magnetic confinement fusion research
article

Experimental and theoretical study of used GFRP I-profile composite columns

article en

Abstract

Glass Fiber Reinforced Polymer (GFRP) is a promising alternative to steel due to its high strength, lightweight properties, corrosion resistance, and low maintenance requirements. This study examines the effect of internal GFRP I-sections on the axial load capacity and fire resistance of reinforced concrete (RC) columns. The experimental program consisted of two groups: the first group, conventional RC columns, with one exposed to 500°C for 90 minutes and the other unheated, and the second group, GFRP I-section reinforced columns, similarly tested under fire and control conditions. Results show that GFRP-reinforced columns exhibited a 17% higher axial capacity than conventional RC columns. However, fire exposure reduced the axial strength of GFRP-reinforced columns by 39% compared to unheated specimens and by 14% compared to conventional RC columns. Theoretical axial load capacities were calculated using design codes, and finite element analysis (FEA) validated the experimental results. Additional parameters, including concrete strength, steel yield strength, reinforcement ratio, and GFRP section properties, were analyzed. The strong correlation between experimental, theoretical, and numerical results provides a foundation for developing practical design guidelines for GFRP-reinforced composite columns.

SHILAP Revista de lepidopterología
Helwan University (EG)
Sustainable cities and communities
Openalex Percentile: Top 33%
Magnetic confinement fusion research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Experimental and theoretical study of used GFRP I-profile composite columns · SHILAP Revista de lepidopterología (2025) | TGRS Research Map | TGRS