Evaluation of Finger Movement Impairment Level Recognition Method Based on Fugl-Meyer Assessment Using Surface EMG

Subjectivity has been an inherent issue in the conventional Fugl-Meyer assessment, which has been the focus of impairment-level recognition in several studies. This study continues our previous work on the use of EMG to recognize finger movement impairment levels. In contrast to our previous work, this study provided a better and more reliable recognition result with improved experimental settings, such as an increased sampling frequency, EMG channels, and extensive patient data. This study employed two data processing mechanisms, inter-subject cross-validation (ISCV) and data-scaled inter-subject cross-validation (DS-ISCV), resulting in two evaluation methods. The machine learning algorithms employed in this study were SVM, random forest (RF), and multi-layer perceptron (MLP). MLP_ISCV achieved the highest average recall score of 0.73 across impairment levels in the spherical grasp task. Subsequently, the highest average recall score of 0.72 among non-majority classes was achieved by SVM_DS-ISCV in the mass extension task. The cross-validation result shows that the proposed method effectively handled the imbalanced dataset without being biased toward the majority class. The proposed method demonstrated the potential to assist doctors in clarifying the subjective assessment of finger movement impairment levels.

Publication Details

Journal
Kobe University Repository Kernel (Kobe University)
Published
2024-12-01
Primary Topic
Magnetic confinement fusion research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Finger Movement Impairment Level Recognition Method Based on Fugl-Meyer Assessment Using Surface EMG

Kobe University Repository Kernel (Kobe University)
Magnetic confinement fusion research
article

Evaluation of Finger Movement Impairment Level Recognition Method Based on Fugl-Meyer Assessment Using Surface EMG

article en

Abstract

Subjectivity has been an inherent issue in the conventional Fugl-Meyer assessment, which has been the focus of impairment-level recognition in several studies. This study continues our previous work on the use of EMG to recognize finger movement impairment levels. In contrast to our previous work, this study provided a better and more reliable recognition result with improved experimental settings, such as an increased sampling frequency, EMG channels, and extensive patient data. This study employed two data processing mechanisms, inter-subject cross-validation (ISCV) and data-scaled inter-subject cross-validation (DS-ISCV), resulting in two evaluation methods. The machine learning algorithms employed in this study were SVM, random forest (RF), and multi-layer perceptron (MLP). MLP_ISCV achieved the highest average recall score of 0.73 across impairment levels in the spherical grasp task. Subsequently, the highest average recall score of 0.72 among non-majority classes was achieved by SVM_DS-ISCV in the mass extension task. The cross-validation result shows that the proposed method effectively handled the imbalanced dataset without being biased toward the majority class. The proposed method demonstrated the potential to assist doctors in clarifying the subjective assessment of finger movement impairment levels.

Kobe University Repository Kernel (Kobe University)
Universitas Airlangga
Openalex Percentile: Top 21%
Magnetic confinement fusion research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.