Double C-Loop Haptic Lenses Are Rotationally Stable – A Systematic Review

Sheraz Daya,1 Christophe Chassain,2 Christophe Pagnoulle3 1Centre for Sight, East Grinstead, West Sussex, UK; 2Clinique Beau Soleil, Montpellier, France; 3Research and Development Department, BVI, Liège, BelgiumCorrespondence: Christophe Pagnoulle, Research and Development Department, BVI.All. des Noisetiers 4, Liège, 4031, Belgium, Email [email protected]: The purpose of this review is to summarize the clinical rotational stability outcomes reported in patients following implantation of the POD platform with double C-loop haptics. A literature search in PubMed (US National Library of Medicine) was carried out to find publications, both prospective and retrospective, which report rotational stability outcomes in patients who were implanted with this platform after cataract or refractive lens exchange surgeries. This platform is used in different commercially available intraocular lenses (IOLs), both monofocal and trifocal, made of hydrophilic or hydrophobic material. 19 clinical peer-reviewed studies published between 2013 and 2024 were included in this review. The data reported in the clinical publications was analyzed in detail, focusing on rotational stability (mean rotation values and ranges, and percentage of eyes with some degrees of rotation), measurement methods and rotation follow-up period. Our review encompassed a total of 1428 eyes implanted with the POD platform analyzed at different follow-up periods, up to a maximum of 26 months. The mean rotation across all the studies was 2.61 °.The analysis carried out in this review leads us to conclude that the POD platform provides good rotational stability when used with different IOL models based on monofocal or trifocal designs and made using hydrophilic or hydrophobic material.Keywords: rotational stability, haptic, double C-loop, intraocular lens, platform

Publication Details

Journal
Dove Medical Press (Taylor and Francis Group)
Published
2025-07-12
Primary Topic
Advanced Optical Sensing Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Double C-Loop Haptic Lenses Are Rotationally Stable – A Systematic Review

Dove Medical Press (Taylor and Francis Group)
Advanced Optical Sensing Technologies
article

Double C-Loop Haptic Lenses Are Rotationally Stable – A Systematic Review

article en

Abstract

Sheraz Daya,1 Christophe Chassain,2 Christophe Pagnoulle3 1Centre for Sight, East Grinstead, West Sussex, UK; 2Clinique Beau Soleil, Montpellier, France; 3Research and Development Department, BVI, Liège, BelgiumCorrespondence: Christophe Pagnoulle, Research and Development Department, BVI.All. des Noisetiers 4, Liège, 4031, Belgium, Email [email protected]: The purpose of this review is to summarize the clinical rotational stability outcomes reported in patients following implantation of the POD platform with double C-loop haptics. A literature search in PubMed (US National Library of Medicine) was carried out to find publications, both prospective and retrospective, which report rotational stability outcomes in patients who were implanted with this platform after cataract or refractive lens exchange surgeries. This platform is used in different commercially available intraocular lenses (IOLs), both monofocal and trifocal, made of hydrophilic or hydrophobic material. 19 clinical peer-reviewed studies published between 2013 and 2024 were included in this review. The data reported in the clinical publications was analyzed in detail, focusing on rotational stability (mean rotation values and ranges, and percentage of eyes with some degrees of rotation), measurement methods and rotation follow-up period. Our review encompassed a total of 1428 eyes implanted with the POD platform analyzed at different follow-up periods, up to a maximum of 26 months. The mean rotation across all the studies was 2.61 °.The analysis carried out in this review leads us to conclude that the POD platform provides good rotational stability when used with different IOL models based on monofocal or trifocal designs and made using hydrophilic or hydrophobic material.Keywords: rotational stability, haptic, double C-loop, intraocular lens, platform

Dove Medical Press (Taylor and Francis Group)
Industry, innovation and infrastructure
Openalex Percentile: Top 40%
Advanced Optical Sensing Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Double C-Loop Haptic Lenses Are Rotationally Stable – A Systematic Review · Dove Medical Press (Taylor and Francis Group) (2025) | TGRS Research Map | TGRS