Cooling System for Data Centers Based on the Air-Water-Air Principle with Increased Temperature Differential

Improving the energy efficiency of data centers by conserving energy in cooling systems is a priority strategy. In this study, thermal analysis of the prevailing air-water-air cooling system revealed inefficiencies caused by a significant discrepancy in the flow rate between the air and water sides of the server room air conditioning system. To mitigate such discrepancy, a new system architecture with a high-temperature differential on the waterside was proposed. Compared with a conventional system with a small temperature differential, the proposed high-temperature differential cooling system substantially augmented the proportion of natural cooling throughout the year, reduced the energy consumption of pumping fluids, and reduced the total energy consumption of the cooling system by approximately 20%-30%. Although the introduction of a high-temperature differential cooling system requires an increase in the heat exchange area and an increase in the cost of air conditioning for the server room, it concurrently reduces the investment in cooling towers, chillers, circulating pumps, chilled water storage tanks, pipelines, and valves, ultimately reducing the total investment in the cooling system by 15%-25%. Furthermore, the high-temperature differential cooling system facilitates operational adjustments, decouples control from external temperature variations and IT load changes, and minimizes maintenance requirements.

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-06-01
Primary Topic
Magnetic confinement fusion research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cooling System for Data Centers Based on the Air-Water-Air Principle with Increased Temperature Differential

SHILAP Revista de lepidopterología
Magnetic confinement fusion research
article

Cooling System for Data Centers Based on the Air-Water-Air Principle with Increased Temperature Differential

article en

Abstract

Improving the energy efficiency of data centers by conserving energy in cooling systems is a priority strategy. In this study, thermal analysis of the prevailing air-water-air cooling system revealed inefficiencies caused by a significant discrepancy in the flow rate between the air and water sides of the server room air conditioning system. To mitigate such discrepancy, a new system architecture with a high-temperature differential on the waterside was proposed. Compared with a conventional system with a small temperature differential, the proposed high-temperature differential cooling system substantially augmented the proportion of natural cooling throughout the year, reduced the energy consumption of pumping fluids, and reduced the total energy consumption of the cooling system by approximately 20%-30%. Although the introduction of a high-temperature differential cooling system requires an increase in the heat exchange area and an increase in the cost of air conditioning for the server room, it concurrently reduces the investment in cooling towers, chillers, circulating pumps, chilled water storage tanks, pipelines, and valves, ultimately reducing the total investment in the cooling system by 15%-25%. Furthermore, the high-temperature differential cooling system facilitates operational adjustments, decouples control from external temperature variations and IT load changes, and minimizes maintenance requirements.

SHILAP Revista de lepidopterología
Affordable and clean energy
Openalex Percentile: Top 34%
Magnetic confinement fusion research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Cooling System for Data Centers Based on the Air-Water-Air Principle with Increased Temperature Differential · SHILAP Revista de lepidopterología (2025) | TGRS Research Map | TGRS