Design and Performance Evaluation of a Novel Time Measurement Calibration Device for Electric Power Systems

In order to solve the difficulty of digital signal calibration of electric power equipment, such as low precision, inability to test the full range, and complicated configuration, and further promote the development of power system, a proposed time measurement calibration device is designed, and its performance is verified in this paper. This paper points out the main drawbacks of the existing calibration system, carries on the design innovation of the key technologies based on FPGA (Field Programmable Gate Array), puts forward the optimization method of the software and hardware, and verifies the accuracy of the input and output signal by experiments. The accuracy of input and output SV, GOOSE, and contact signal of the proposed calibration device in this paper can be better than 10μs, which is a meaningful improvement in accuracy and efficiency for time measurement calibration.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-06-01
Primary Topic
Magnetic confinement fusion research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Performance Evaluation of a Novel Time Measurement Calibration Device for Electric Power Systems

SHILAP Revista de lepidopterología
Magnetic confinement fusion research
article

Design and Performance Evaluation of a Novel Time Measurement Calibration Device for Electric Power Systems

article en

Abstract

In order to solve the difficulty of digital signal calibration of electric power equipment, such as low precision, inability to test the full range, and complicated configuration, and further promote the development of power system, a proposed time measurement calibration device is designed, and its performance is verified in this paper. This paper points out the main drawbacks of the existing calibration system, carries on the design innovation of the key technologies based on FPGA (Field Programmable Gate Array), puts forward the optimization method of the software and hardware, and verifies the accuracy of the input and output signal by experiments. The accuracy of input and output SV, GOOSE, and contact signal of the proposed calibration device in this paper can be better than 10μs, which is a meaningful improvement in accuracy and efficiency for time measurement calibration.

SHILAP Revista de lepidopterología
Birmingham City University (GB), Swinburne University of Technology (AU), Universiti Malaysia Perlis (MY), Swinburne University of Technology Sarawak Campus (MY)
Industry, innovation and infrastructure
Openalex Percentile: Top 35%
Magnetic confinement fusion research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.