Comparison of Biometric Measurements and IOL Power Calculation Between a Swept-Source OCT and an Optical Low-Coherence Reflectometry Biometer

Daniel Romero,1 Carlos E Monera,1 David Cooke,2 Jorge L Alio,3 Claudia Tarazona,1 Jose Juan Martínez-Toldos1 1Department of Ophthalmology, General University Hospital of Elche, Elche Foundation for the Promotion of Health and Biomedical Research in the Valencian Region (FISABIO), Valencia, Spain; 2Great Lakes Eye Care, St. Joseph, MI, USA; 3VISSUM Ophthalmological Institute of Alicante, Alicante, SpainCorrespondence: Daniel Romero, Department of Ophthalmology, General University Hospital of Elche, Carrer de la Almazara 11, Elche, Alicante, CP 03203, Spain, Email [email protected]: To evaluate the comparability of biometric measurements obtained using the swept-source optical coherence tomography (SS-OCT) biometer (Anterion) and the optical low-coherence reflectometry (OLCR) biometer (Lenstar LS900).Methods: This observational study included 150 cataract patients undergoing preoperative biometry at the General University Hospital of Elche. Measurements from the Anterion and Lenstar LS900 were compared for axial length (AL), mean keratometry (Km), anterior chamber depth (ACD), lens thickness (LT), and central corneal thickness (CCT). Bland-Altman plots and statistical analyses were conducted to assess differences and correlations.Results: The mean AL measurements showed no significant difference between the two devices (mean difference − 0.004 ± 0.053 mm, P = 0.420). ACD and LT measurements displayed statistically significant differences, with Anterion showing greater mean values (ACD difference: 0.054 ± 0.037 mm, P < 0.001; LT difference: 0.107 ± 0.079 mm, P < 0.001). Mean keratometry was significantly flatter by 0.074 ± 0.259D (P = 0.001) in Anterion compared to Lenstar, primarily due to differences in steep keratometry. No correlation was found between keratometry differences and corneal asphericity. Estimated intraocular lens (IOL) power for emmetropia was significantly higher using Anterion by 0.146 ± 0.398D (P < 0.001), necessitating an A-constant adjustment of approximately 0.16 to equal mean IOL power in both devices.Conclusion: a good correlation was found between both biometers. However, due to the differences found between biometric measurements between devices, these two biometers should not be considered interchangeable and clinicians should adjust IOL constants accordingly. Future studies will be necessary to determine whether one biometer is superior to the other in terms of refractive outcome predictability.Keywords: biometry, swept-source optical coherence tomography, optical low-coherence reflectometry, anterion, Lenstar LS900, IOL power calculation, cataract surgery

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-06-01
Primary Topic
Magnetic confinement fusion research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Biometric Measurements and IOL Power Calculation Between a Swept-Source OCT and an Optical Low-Coherence Reflectometry Biometer

SHILAP Revista de lepidopterología
Magnetic confinement fusion research
article

Comparison of Biometric Measurements and IOL Power Calculation Between a Swept-Source OCT and an Optical Low-Coherence Reflectometry Biometer

article en

Abstract

Daniel Romero,1 Carlos E Monera,1 David Cooke,2 Jorge L Alio,3 Claudia Tarazona,1 Jose Juan Martínez-Toldos1 1Department of Ophthalmology, General University Hospital of Elche, Elche Foundation for the Promotion of Health and Biomedical Research in the Valencian Region (FISABIO), Valencia, Spain; 2Great Lakes Eye Care, St. Joseph, MI, USA; 3VISSUM Ophthalmological Institute of Alicante, Alicante, SpainCorrespondence: Daniel Romero, Department of Ophthalmology, General University Hospital of Elche, Carrer de la Almazara 11, Elche, Alicante, CP 03203, Spain, Email [email protected]: To evaluate the comparability of biometric measurements obtained using the swept-source optical coherence tomography (SS-OCT) biometer (Anterion) and the optical low-coherence reflectometry (OLCR) biometer (Lenstar LS900).Methods: This observational study included 150 cataract patients undergoing preoperative biometry at the General University Hospital of Elche. Measurements from the Anterion and Lenstar LS900 were compared for axial length (AL), mean keratometry (Km), anterior chamber depth (ACD), lens thickness (LT), and central corneal thickness (CCT). Bland-Altman plots and statistical analyses were conducted to assess differences and correlations.Results: The mean AL measurements showed no significant difference between the two devices (mean difference − 0.004 ± 0.053 mm, P = 0.420). ACD and LT measurements displayed statistically significant differences, with Anterion showing greater mean values (ACD difference: 0.054 ± 0.037 mm, P < 0.001; LT difference: 0.107 ± 0.079 mm, P < 0.001). Mean keratometry was significantly flatter by 0.074 ± 0.259D (P = 0.001) in Anterion compared to Lenstar, primarily due to differences in steep keratometry. No correlation was found between keratometry differences and corneal asphericity. Estimated intraocular lens (IOL) power for emmetropia was significantly higher using Anterion by 0.146 ± 0.398D (P < 0.001), necessitating an A-constant adjustment of approximately 0.16 to equal mean IOL power in both devices.Conclusion: a good correlation was found between both biometers. However, due to the differences found between biometric measurements between devices, these two biometers should not be considered interchangeable and clinicians should adjust IOL constants accordingly. Future studies will be necessary to determine whether one biometer is superior to the other in terms of refractive outcome predictability.Keywords: biometry, swept-source optical coherence tomography, optical low-coherence reflectometry, anterion, Lenstar LS900, IOL power calculation, cataract surgery

SHILAP Revista de lepidopterología
Openalex Percentile: Top 36%
Magnetic confinement fusion research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.