ANALYSIS AND VIBRATION REDUCTION STUDY OF ABNORMAL VIBRATION IN THE PIPELINE OF ULTRA-HIGH VOLTAGE CONVERTER STATION SYNCHRONOUS CONDENSER

Abnormal vibration in the pipeline associated with large synchronous condensers not only reduces the lifespan of the pipeline but also affects the supply of the lubricating oil and coolant for the synchronous condenser, posing a serious risk of major safety accidents and jeopardizing the stability of the power system. The lubricating oil supply pipeline of a specific ultra-high voltage converter station synchronous condenser was taken as the research object. Multiple methods, including field measurements, fluid-structure coupling, and harmonic response analysis, were used to investigate the causes and mechanisms of the pipeline vibration. The results indicate that the periodic excitation force generated by the synchronous condenser itself is the main cause of pipeline vibration. Furthermore, a pipeline vibration reduction measure based on a tuned mass damper (TMD) was proposed. Experimental and simulation data shows that installing a TMD at the intermediate positions between suspension supports 4 and 5, as well as 6 and 7 in the lubricating oil supply pipeline system, yields the best vibration reduction effect. This approach can reduce the vibration acceleration of the pipeline system by over 90% and exhibits the excellent vibration reduction performance.

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-05-01
Primary Topic
Magnetic confinement fusion research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ANALYSIS AND VIBRATION REDUCTION STUDY OF ABNORMAL VIBRATION IN THE PIPELINE OF ULTRA-HIGH VOLTAGE CONVERTER STATION SYNCHRONOUS CONDENSER

SHILAP Revista de lepidopterología
Magnetic confinement fusion research
article

ANALYSIS AND VIBRATION REDUCTION STUDY OF ABNORMAL VIBRATION IN THE PIPELINE OF ULTRA-HIGH VOLTAGE CONVERTER STATION SYNCHRONOUS CONDENSER

article en

Abstract

Abnormal vibration in the pipeline associated with large synchronous condensers not only reduces the lifespan of the pipeline but also affects the supply of the lubricating oil and coolant for the synchronous condenser, posing a serious risk of major safety accidents and jeopardizing the stability of the power system. The lubricating oil supply pipeline of a specific ultra-high voltage converter station synchronous condenser was taken as the research object. Multiple methods, including field measurements, fluid-structure coupling, and harmonic response analysis, were used to investigate the causes and mechanisms of the pipeline vibration. The results indicate that the periodic excitation force generated by the synchronous condenser itself is the main cause of pipeline vibration. Furthermore, a pipeline vibration reduction measure based on a tuned mass damper (TMD) was proposed. Experimental and simulation data shows that installing a TMD at the intermediate positions between suspension supports 4 and 5, as well as 6 and 7 in the lubricating oil supply pipeline system, yields the best vibration reduction effect. This approach can reduce the vibration acceleration of the pipeline system by over 90% and exhibits the excellent vibration reduction performance.

SHILAP Revista de lepidopterología
Openalex Percentile: Top 38%
Magnetic confinement fusion research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.