Варіанти конструктивних рішень первинного контуру ТН «повітря-вода» для схем теплопостачання приватних житлових будинків

The article discusses options for arranging the primary circuit of air-to-water heat pumps. From the point of view of capital costs and construction time, the air-to-water heat pump is the most profitable. However, it has a significant drawback: a drop in heat output when the outside air temperature decreases, precisely when the need for heat increases.To cover peak heat loads, the heating system is equipped with a redundant heat source - usually an electric heating unit. The search for ways to eliminate or significantly reduce the dependence of the heat output of air heaters on the outside air temperature is represented by three variants of the evaporator design of an air-to-water heat pump: with a ‘classical’ heat exchanger in the form of copper tubes with aluminium fins and forced air movement by means of a fan; with a vertical copper-tube heat exchanger with aluminium fins and free air movement - Octopus; and with a heat exchanger in the form of a manor fence - a single-row pipe regime made of polyethylene pipes (German technology Energiezaun). Calculations of the surface of the energy fence for a residential building in Odesa are presented.

Institutions

Publication Details

Journal
Scientific periodicals of Ukraine
Published
2024-12-25
Primary Topic
Nuclear reactor physics and engineering
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Варіанти конструктивних рішень первинного контуру ТН «повітря-вода» для схем теплопостачання приватних житлових будинків

Scientific periodicals of Ukraine
Nuclear reactor physics and engineering
article

Варіанти конструктивних рішень первинного контуру ТН «повітря-вода» для схем теплопостачання приватних житлових будинків

article en

Abstract

The article discusses options for arranging the primary circuit of air-to-water heat pumps. From the point of view of capital costs and construction time, the air-to-water heat pump is the most profitable. However, it has a significant drawback: a drop in heat output when the outside air temperature decreases, precisely when the need for heat increases.To cover peak heat loads, the heating system is equipped with a redundant heat source - usually an electric heating unit. The search for ways to eliminate or significantly reduce the dependence of the heat output of air heaters on the outside air temperature is represented by three variants of the evaporator design of an air-to-water heat pump: with a ‘classical’ heat exchanger in the form of copper tubes with aluminium fins and forced air movement by means of a fan; with a vertical copper-tube heat exchanger with aluminium fins and free air movement - Octopus; and with a heat exchanger in the form of a manor fence - a single-row pipe regime made of polyethylene pipes (German technology Energiezaun). Calculations of the surface of the energy fence for a residential building in Odesa are presented.

Scientific periodicals of Ukraine
Bio-Medical Science (South Korea) (KR)
Sustainable cities and communities
Openalex Percentile: Top 20%
Nuclear reactor physics and engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.