Вплив блокування отворів видуву охолоджувача на ефективність плівкового охолодження

The article is devoted to the computer simulation of film cooling of a flat plate with the supply of a secondary flow in a series of inclined holes with their partial blocking. Calculations were performed in the commercial ANSYS CFX 2019 R2 software complex with a change in the injection parameter from 0.5 to 1.5, which were selected according to real conditions, using the SST turbulence model. When the blocking parameter increases from 0.5 to 1.5, the film cooling efficiency decreases by 3.1 %, 6.7 %, and 10.6 %, respectively, compared to the traditional scheme without blocking. As the blow-in parameter increases, significant non-uniformity of film cooling efficiency remains over the entire length of the plate, with pronounced maxima along the axis of the cooler blow holes and minima in the region between the holes. On the other hand, a pronounced symmetry is preserved on each configuration of the plate. As the analysis of the distribution of the local effectiveness of the film cooling on the plane of the plate for each blocking configuration showed, the effectiveness of the film cooling uniformly decreases with an increase in the blowing parameter.

Institutions

Publication Details

Journal
The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy
Published
2025-04-30
Primary Topic
Particle accelerators and beam dynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Вплив блокування отворів видуву охолоджувача на ефективність плівкового охолодження

The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy
Particle accelerators and beam dynamics
article

Вплив блокування отворів видуву охолоджувача на ефективність плівкового охолодження

article en

Abstract

The article is devoted to the computer simulation of film cooling of a flat plate with the supply of a secondary flow in a series of inclined holes with their partial blocking. Calculations were performed in the commercial ANSYS CFX 2019 R2 software complex with a change in the injection parameter from 0.5 to 1.5, which were selected according to real conditions, using the SST turbulence model. When the blocking parameter increases from 0.5 to 1.5, the film cooling efficiency decreases by 3.1 %, 6.7 %, and 10.6 %, respectively, compared to the traditional scheme without blocking. As the blow-in parameter increases, significant non-uniformity of film cooling efficiency remains over the entire length of the plate, with pronounced maxima along the axis of the cooler blow holes and minima in the region between the holes. On the other hand, a pronounced symmetry is preserved on each configuration of the plate. As the analysis of the distribution of the local effectiveness of the film cooling on the plane of the plate for each blocking configuration showed, the effectiveness of the film cooling uniformly decreases with an increase in the blowing parameter.

The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy
Institute of Endocrinology (CZ)
Affordable and clean energy
Openalex Percentile: Top 35%
Particle accelerators and beam dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Вплив блокування отворів видуву охолоджувача на ефективність плівкового охолодження · The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy (2025) | TGRS Research Map | TGRS