Using Wearable Sensors for Gait Analysis: Measurement Accuracy for Linear Measurements

Measurement and analysis of human movement are necessary in a broad range of clinical, sports performance, and artistic applications. Historically, motion data were typically collected using optical motion capture systems. However, these systems are expensive and can only be used in lab spaces, which limits the range and speeds of human behavior. More recently, inexpensive, wearable sensors called Inertial Measurement Units (IMUs) have enabled motion measurement in natural settings, but these systems require validation before use. In this study, we evaluate measurement accuracy for linear displacements obtained using Sparkfun OpenLog Artemis IMUs. We conducted a series of tests, moving the sensor along predetermined distances in different directions and evaluating its ability to capture displacement accurately. IMU data were processed using custom MATLAB algorithms to calibrate, filter, and double-integrate acceleration data to obtain recorded linear displacements in all three planes of motion (e.g., x, y, and z axes). Our results indicated that the IMUs could not accurately measure linear displacements, with average measurement errors ranging from 22.5% to 83.7%. We also found that the degree of measurement error differed based on the direction of measurement for this device. These results indicate that additional calibration steps should be pursued before using these devices for clinical distance measurement. In the future, we will incorporate an assessment of device accuracy to operating temperature and sensitivity settings, as well as inter-device error variation. This research is part of a larger series of IMU validation experiments that, if successful, will enable inexpensive IMU-based measurement of human motion with a broad range of applications.

Publication Details

Journal
Scholars Archive - University at Albany (University at Albany, State University of New York)
Published
2025-05-01
Primary Topic
Adaptive optics and wavefront sensing
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Using Wearable Sensors for Gait Analysis: Measurement Accuracy for Linear Measurements

Scholars Archive - University at Albany (University at Albany, State University of New York)
Adaptive optics and wavefront sensing
article

Using Wearable Sensors for Gait Analysis: Measurement Accuracy for Linear Measurements

article en

Abstract

Measurement and analysis of human movement are necessary in a broad range of clinical, sports performance, and artistic applications. Historically, motion data were typically collected using optical motion capture systems. However, these systems are expensive and can only be used in lab spaces, which limits the range and speeds of human behavior. More recently, inexpensive, wearable sensors called Inertial Measurement Units (IMUs) have enabled motion measurement in natural settings, but these systems require validation before use. In this study, we evaluate measurement accuracy for linear displacements obtained using Sparkfun OpenLog Artemis IMUs. We conducted a series of tests, moving the sensor along predetermined distances in different directions and evaluating its ability to capture displacement accurately. IMU data were processed using custom MATLAB algorithms to calibrate, filter, and double-integrate acceleration data to obtain recorded linear displacements in all three planes of motion (e.g., x, y, and z axes). Our results indicated that the IMUs could not accurately measure linear displacements, with average measurement errors ranging from 22.5% to 83.7%. We also found that the degree of measurement error differed based on the direction of measurement for this device. These results indicate that additional calibration steps should be pursued before using these devices for clinical distance measurement. In the future, we will incorporate an assessment of device accuracy to operating temperature and sensitivity settings, as well as inter-device error variation. This research is part of a larger series of IMU validation experiments that, if successful, will enable inexpensive IMU-based measurement of human motion with a broad range of applications.

Scholars Archive - University at Albany (University at Albany, State University of New York)
Openalex Percentile: Top 48%
Adaptive optics and wavefront sensing
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Using Wearable Sensors for Gait Analysis: Measurement Accuracy for Linear Measurements · Scholars Archive - University at Albany (University at Albany, State University of New York) (2025) | TGRS Research Map | TGRS