Thermal Switch Characteristics of a Multi-channel Parallel Pulsating Heat Pipe

An experimental platform was built to evaluate the thermal switching performance of a parallel pulsating multi-channel heat pipe using fluoroether HFE-7100 as the working fluid with a liquid filling ratio of 80%. The heating and cooling temperatures of the pulsating heat pipe were controlled using water baths for heating and cooling. The thermal switching characteristics of the pulsating heat pipe at different cooling temperatures were investigated experimentally. The results showed that after the complete start-up of the multi-channel parallel pulsating heat pipe, the average temperature of the evaporation section decreased, the average temperature of the condensation section increased, the thermal resistance decreased, and the heat transfer performance improved rapidly. The temperature and thermal resistance transient processes exhibited a sudden step change, which can be used as a thermal switch. As the cooling temperature increased, the closing time of the thermal switch and the switch temperature increased. At a cooling temperature of 10 ℃, the closing time of the thermal switch was 12 s, and the switch temperature was 59.3 ℃. At higher cooling temperatures, the thermal switch performed better, characterized by a greater increase in the switch ratio and heat transfer rate. When the cooling temperature was 30 ℃, the heat transfer rate increased by 26.8 W following the closure of the thermal switch, with a switch ratio of 5.05.

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-06-01
Primary Topic
Adaptive optics and wavefront sensing
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermal Switch Characteristics of a Multi-channel Parallel Pulsating Heat Pipe

SHILAP Revista de lepidopterología
Adaptive optics and wavefront sensing
article

Thermal Switch Characteristics of a Multi-channel Parallel Pulsating Heat Pipe

article en

Abstract

An experimental platform was built to evaluate the thermal switching performance of a parallel pulsating multi-channel heat pipe using fluoroether HFE-7100 as the working fluid with a liquid filling ratio of 80%. The heating and cooling temperatures of the pulsating heat pipe were controlled using water baths for heating and cooling. The thermal switching characteristics of the pulsating heat pipe at different cooling temperatures were investigated experimentally. The results showed that after the complete start-up of the multi-channel parallel pulsating heat pipe, the average temperature of the evaporation section decreased, the average temperature of the condensation section increased, the thermal resistance decreased, and the heat transfer performance improved rapidly. The temperature and thermal resistance transient processes exhibited a sudden step change, which can be used as a thermal switch. As the cooling temperature increased, the closing time of the thermal switch and the switch temperature increased. At a cooling temperature of 10 ℃, the closing time of the thermal switch was 12 s, and the switch temperature was 59.3 ℃. At higher cooling temperatures, the thermal switch performed better, characterized by a greater increase in the switch ratio and heat transfer rate. When the cooling temperature was 30 ℃, the heat transfer rate increased by 26.8 W following the closure of the thermal switch, with a switch ratio of 5.05.

SHILAP Revista de lepidopterología
Affordable and clean energy
Openalex Percentile: Top 48%
Adaptive optics and wavefront sensing
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Thermal Switch Characteristics of a Multi-channel Parallel Pulsating Heat Pipe · SHILAP Revista de lepidopterología (2025) | TGRS Research Map | TGRS