Right Internal Jugular Vein Access for Micra Leadless Pacemaker Implantation in a High-Risk Patient with Severe Iliac Vein Stenosis: A Case Report

Haixiang Xu, Jianfeng Qian, Wen Pan, Jianhua Fan Department of Cardiology, Kunshan Hospital of Traditional Chinese Medicine Affiliated to Yangzhou University, Suzhou, People’s Republic of ChinaCorrespondence: Jianhua Fan, Department of Cardiology, Kunshan Hospital of Traditional Chinese Medicine Affiliated to Yangzhou University, Suzhou, People’s Republic of China, Email [email protected]: Leadless pacemakers offer a promising alternative to traditional transvenous pacemakers, especially in patients with complex vascular anatomy or a high risk of infection. Conventional access routes may be compromised in patients with significant venous stenosis or prior vascular interventions, requiring alternative strategies for device implantation.Case Presentation: We report the case of a 74-year-old female with sick sinus syndrome, chronic kidney disease, type 2 diabetes, and severe bilateral iliac vein stenosis, who was deemed high-risk for conventional pacemaker implantation. After failed attempts through both femoral veins, the right internal jugular vein (RIJV) was successfully used as an alternative access route for Micra leadless pacemaker implantation. The procedure was performed under ultrasound and fluoroscopic guidance without complications. Post-procedure, the pacing threshold was 0.75 V, sensing was 8.5 mV, and impedance was 760 Ω, all within normal limits.Conclusion: This case highlights the feasibility and safety of using the right internal jugular vein as an alternative access route for leadless pacemaker implantation in high-risk patients when femoral access is not possible. This approach provides a valuable option for patients with complex venous anatomy, contributing to the broader application of leadless pacing technology.Keywords: micra leadless pacemaker, right internal jugular vein, iliac vein stenosis, high-risk patient, alternative access

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-06-01
Primary Topic
Thermal Analysis in Power Transmission
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Right Internal Jugular Vein Access for Micra Leadless Pacemaker Implantation in a High-Risk Patient with Severe Iliac Vein Stenosis: A Case Report

SHILAP Revista de lepidopterología
Thermal Analysis in Power Transmission
article

Right Internal Jugular Vein Access for Micra Leadless Pacemaker Implantation in a High-Risk Patient with Severe Iliac Vein Stenosis: A Case Report

article en

Abstract

Haixiang Xu, Jianfeng Qian, Wen Pan, Jianhua Fan Department of Cardiology, Kunshan Hospital of Traditional Chinese Medicine Affiliated to Yangzhou University, Suzhou, People’s Republic of ChinaCorrespondence: Jianhua Fan, Department of Cardiology, Kunshan Hospital of Traditional Chinese Medicine Affiliated to Yangzhou University, Suzhou, People’s Republic of China, Email [email protected]: Leadless pacemakers offer a promising alternative to traditional transvenous pacemakers, especially in patients with complex vascular anatomy or a high risk of infection. Conventional access routes may be compromised in patients with significant venous stenosis or prior vascular interventions, requiring alternative strategies for device implantation.Case Presentation: We report the case of a 74-year-old female with sick sinus syndrome, chronic kidney disease, type 2 diabetes, and severe bilateral iliac vein stenosis, who was deemed high-risk for conventional pacemaker implantation. After failed attempts through both femoral veins, the right internal jugular vein (RIJV) was successfully used as an alternative access route for Micra leadless pacemaker implantation. The procedure was performed under ultrasound and fluoroscopic guidance without complications. Post-procedure, the pacing threshold was 0.75 V, sensing was 8.5 mV, and impedance was 760 Ω, all within normal limits.Conclusion: This case highlights the feasibility and safety of using the right internal jugular vein as an alternative access route for leadless pacemaker implantation in high-risk patients when femoral access is not possible. This approach provides a valuable option for patients with complex venous anatomy, contributing to the broader application of leadless pacing technology.Keywords: micra leadless pacemaker, right internal jugular vein, iliac vein stenosis, high-risk patient, alternative access

SHILAP Revista de lepidopterología
Institute of Cardiology (PL)
Openalex Percentile: Top 44%
Thermal Analysis in Power Transmission
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.