Investigation of Thermoluminescence Properties of Calcite from Kaman, Kırşehir

This study investigates the thermoluminescence (TL) properties and dosimetric performance of calcite samples, with particular emphasis on dose response, heating rate (HR) effects, and reusability (RU). TL measurements were carried out using a Lexsyg Smart TL/OSL reader equipped with a ⁹⁰Sr/⁹⁰Y beta source. The dose-response relationship was analyzed by irradiating the sample with beta doses ranging from 0.1 to 500 Gy, revealed a progressive increase in TL intensity. The TL glow curve exhibited two broad peaks at 100-116 °C and 238 °C, with a shift in the first peak temperature at higher doses. A fitting procedure was applied to analyze the dose-response characteristics of the material, revealing distinct b values for different dose ranges. The effect of HR on the glow curve was also studied, showing an anomalous increase in TL intensity with rising HRs, contrary to expectations from the standard theoretical model. Additionally, the RU of the material was assessed by performing 10 consecutive TL measurements after a 50 Gy irradiation, demonstrating minimal degradation in TL intensity, with low deviations from the mean and first values. This remarkable RU is crucial for ensuring the material's effectiveness in long-term dosimetric applications.

Publication Details

Journal
DergiPark (Istanbul University)
Published
2025-03-21
Primary Topic
Magnetic confinement fusion research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of Thermoluminescence Properties of Calcite from Kaman, Kırşehir

DergiPark (Istanbul University)
Magnetic confinement fusion research
article

Investigation of Thermoluminescence Properties of Calcite from Kaman, Kırşehir

article en

Abstract

This study investigates the thermoluminescence (TL) properties and dosimetric performance of calcite samples, with particular emphasis on dose response, heating rate (HR) effects, and reusability (RU). TL measurements were carried out using a Lexsyg Smart TL/OSL reader equipped with a ⁹⁰Sr/⁹⁰Y beta source. The dose-response relationship was analyzed by irradiating the sample with beta doses ranging from 0.1 to 500 Gy, revealed a progressive increase in TL intensity. The TL glow curve exhibited two broad peaks at 100-116 °C and 238 °C, with a shift in the first peak temperature at higher doses. A fitting procedure was applied to analyze the dose-response characteristics of the material, revealing distinct b values for different dose ranges. The effect of HR on the glow curve was also studied, showing an anomalous increase in TL intensity with rising HRs, contrary to expectations from the standard theoretical model. Additionally, the RU of the material was assessed by performing 10 consecutive TL measurements after a 50 Gy irradiation, demonstrating minimal degradation in TL intensity, with low deviations from the mean and first values. This remarkable RU is crucial for ensuring the material's effectiveness in long-term dosimetric applications.

DergiPark (Istanbul University)
Openalex Percentile: Top 50%
Magnetic confinement fusion research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.