Determining Optimal Home Oxygen Flow Rate For Infants With Bronchopulmonary Dysplasia (BPD) Using Near Infrared Spectroscopy

Ahmad A Imran,1 Jagmeet Singh Bajwa,2 Sibasis Daspal,1 Darryl J Adamko3 1Division of Neonatology, Department of Pediatrics, University of Saskatchewan, Saskatoon, Saskatchewan, Canada; 2Division of Research, Department of Pediatrics, University of Saskatchewan, Saskatoon, Saskatchewan, Canada; 3Division of Respirology, Department of Pediatrics, University of Saskatchewan, Saskatoon, Saskatchewan, CanadaCorrespondence: Darryl J Adamko, Department of Pediatrics, College of Medicine, 103 hospital Drive, University of Saskatchewan, Saskatoon, SK, S7N 0W8, Canada, Tel +1 306 844-1275, Fax +1 306 844-1210, Email [email protected]: Near-infrared spectroscopy (NIRS) measures cerebral oxygenation and could measure the risk of hypoxia or hyperoxia in infants with bronchopulmonary dysplasia (BPD). We lack normalized data for NIRS values in neonates. We sought normative values of NIRS and proposed that NIRS could better identify a safe oxygen flow rate compared to pulse oximetry (POX).Methods: This prospective cohort study compared POX and NIRS values in healthy infants in room air (n = 22) with BPD infants (n = 10) on oxygen (0.03, 0.06, 0.12 L/min).Results: In healthy infants, the average POX value was 97.8%, and NIRS was 78.24%. Time (% time) with hypoxia was similarly low using either POX or NIRS (3.5% and 1.4%). On oxygen, % time with hypoxemia was similarly low with both POX or NIRS (0.03 lpm: 2.35% POX and 0.01% NIRS; 0.06 lpm: 1.43% POX and 0.6% NIRS; 0.12 lpm: 1.46% POX and 0.2% NIRS). In contrast, the potential hyperoxia %time was higher using POX compared to NIRS (96.5% vs 47.9%) in room air healthy infants. Similarly, hyperoxia %time was more common with POX compared to NIRS, but there was no difference with increasing oxygen flow rates (0.03 lpm, 82.13% POX and 41.5% NIRS; 0.06 lpm: 92.49% POX and 34.4% NIRS; 0.12 lpm: 87.00% POX and 34.8% NIRS).Conclusion: We did not see a dose response correlation between oxygen flow rate and time spent in the hyperoxemic range across different flow rates by POX or cerebral NIRS. We did not see a benefit of NIRS in setting home oxygen flow rates.Keywords: near infrared spectroscopy, hyperoxia, home oxygen

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-12-01
Primary Topic
Particle accelerators and beam dynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determining Optimal Home Oxygen Flow Rate For Infants With Bronchopulmonary Dysplasia (BPD) Using Near Infrared Spectroscopy

SHILAP Revista de lepidopterología
Particle accelerators and beam dynamics
article

Determining Optimal Home Oxygen Flow Rate For Infants With Bronchopulmonary Dysplasia (BPD) Using Near Infrared Spectroscopy

article en

Abstract

Ahmad A Imran,1 Jagmeet Singh Bajwa,2 Sibasis Daspal,1 Darryl J Adamko3 1Division of Neonatology, Department of Pediatrics, University of Saskatchewan, Saskatoon, Saskatchewan, Canada; 2Division of Research, Department of Pediatrics, University of Saskatchewan, Saskatoon, Saskatchewan, Canada; 3Division of Respirology, Department of Pediatrics, University of Saskatchewan, Saskatoon, Saskatchewan, CanadaCorrespondence: Darryl J Adamko, Department of Pediatrics, College of Medicine, 103 hospital Drive, University of Saskatchewan, Saskatoon, SK, S7N 0W8, Canada, Tel +1 306 844-1275, Fax +1 306 844-1210, Email [email protected]: Near-infrared spectroscopy (NIRS) measures cerebral oxygenation and could measure the risk of hypoxia or hyperoxia in infants with bronchopulmonary dysplasia (BPD). We lack normalized data for NIRS values in neonates. We sought normative values of NIRS and proposed that NIRS could better identify a safe oxygen flow rate compared to pulse oximetry (POX).Methods: This prospective cohort study compared POX and NIRS values in healthy infants in room air (n = 22) with BPD infants (n = 10) on oxygen (0.03, 0.06, 0.12 L/min).Results: In healthy infants, the average POX value was 97.8%, and NIRS was 78.24%. Time (% time) with hypoxia was similarly low using either POX or NIRS (3.5% and 1.4%). On oxygen, % time with hypoxemia was similarly low with both POX or NIRS (0.03 lpm: 2.35% POX and 0.01% NIRS; 0.06 lpm: 1.43% POX and 0.6% NIRS; 0.12 lpm: 1.46% POX and 0.2% NIRS). In contrast, the potential hyperoxia %time was higher using POX compared to NIRS (96.5% vs 47.9%) in room air healthy infants. Similarly, hyperoxia %time was more common with POX compared to NIRS, but there was no difference with increasing oxygen flow rates (0.03 lpm, 82.13% POX and 41.5% NIRS; 0.06 lpm: 92.49% POX and 34.4% NIRS; 0.12 lpm: 87.00% POX and 34.8% NIRS).Conclusion: We did not see a dose response correlation between oxygen flow rate and time spent in the hyperoxemic range across different flow rates by POX or cerebral NIRS. We did not see a benefit of NIRS in setting home oxygen flow rates.Keywords: near infrared spectroscopy, hyperoxia, home oxygen

SHILAP Revista de lepidopterología
Openalex Percentile: Top 21%
Particle accelerators and beam dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.