Analysis of discretization errors in microtremor measurements

This study investigates the effects of discretization errors on the analysis of microtremor vibrations measured in a building located in Berovo, using the EQR120 accelerometer. The primary focus is on the impact of discretization on Fourier spectral amplitudes and the accuracy of frequency domain analysis. The results show that with increasing recording time (T), there are more pronounced peaks in the Fourier spectrum, especially for higher frequen-cies. Despite variations in discrete levels of acceleration, the frequency domain response of the instrument remains nearly constant over a wide range of frequencies, resembling white noise. The study highlights that microtremor am-plitudes are generally small, and significant variations in spectral amplitudes were not observed over time in a 24hourmeasurement period. The findings suggest that external excitation with larger forces is needed to observe spectral peaks, particularly in the ground floor movements. The analysis provides valuable insights into the behavior of microtremors in built environments and emphasizes the challenges of capturing small-scale vibrations in densely populated areas.

Publication Details

Journal
Goce Delchev University Repository (Goce Delčev University of Štip)
Published
2025-07-12
Primary Topic
Laser Design and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of discretization errors in microtremor measurements

Goce Delchev University Repository (Goce Delčev University of Štip)
Laser Design and Applications
article

Analysis of discretization errors in microtremor measurements

article en

Abstract

This study investigates the effects of discretization errors on the analysis of microtremor vibrations measured in a building located in Berovo, using the EQR120 accelerometer. The primary focus is on the impact of discretization on Fourier spectral amplitudes and the accuracy of frequency domain analysis. The results show that with increasing recording time (T), there are more pronounced peaks in the Fourier spectrum, especially for higher frequen-cies. Despite variations in discrete levels of acceleration, the frequency domain response of the instrument remains nearly constant over a wide range of frequencies, resembling white noise. The study highlights that microtremor am-plitudes are generally small, and significant variations in spectral amplitudes were not observed over time in a 24hourmeasurement period. The findings suggest that external excitation with larger forces is needed to observe spectral peaks, particularly in the ground floor movements. The analysis provides valuable insights into the behavior of microtremors in built environments and emphasizes the challenges of capturing small-scale vibrations in densely populated areas.

Goce Delchev University Repository (Goce Delčev University of Štip)
Sustainable cities and communities
Openalex Percentile: Top 51%
Laser Design and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.