Дослідження умов формування газорідинного потоку при випуску плавки з конвертера

The study of the conditions for the formation of a gas-liquid flow during the tapping of molten metal from the converter is based on low-temperature modeling, aimed at analyzing the impact of the structural characteristics of the steel tapping channel. The use of inert gas (argon) enabled the creation of a protective gas shell that reduces the contact of the metal with atmospheric oxygen, lowering its content in the flow to 1–3%. Based on the experiments, a classification of blowing regimes and empirical dependencies were developed to describe the interaction between the gas and the liquid. It was established that the minimum oxygen concentration in the gas phase (1–3%) is achieved with an argon flow of 10–20% of the maximum. This maintains the efficiency of the protective shell at 95%. Further increases in the argon flow lead to the expansion of the flow's opening angle, negatively impacting its organization. Increasing the number of nozzles improves flow stability: with six nozzles, the oxygen concentration remains below 10.5%, even with high gas flow rates. Experiments on a flat tapping channel model revealed a dependence between the gas flow, liquid level, and the depth of the vortex. Increasing the gas flow with a high liquid level contributes to the stability of the interfacial surface, whereas reducing the liquid level leads to an increase in vortex depth and deterioration of the flow organization. The experiments were conducted on a laboratory setup simulating the tapping process, accounting for geometric and dynamic similarity. Technically pure argon with an oxygen content of up to 0.7% was used. The main parameters for analysis included gas flow rate, liquid level, relative vortex depth, and flow opening angle. To assess the effectiveness of the gas shell, oxygen concentration was analyzed using a gas analyzer. The proposed optimal conditions include controlling the argon flow rate, liquid level, and the number of nozzles. It was established that an argon flow rate of 0.05–0.125 m³/min ensures effective protection of the melt, and an optimal flow opening angle of up to 3° contributes to efficiency levels of 92–99%. The obtained results are of significant practical importance for improving the tapping process, refining, and reducing steel oxidation. The developed dependencies allow for more accurate determination of blowing parameters and optimization of the tapping channel design, thereby enhancing the efficiency of metallurgical processes

Publication Details

Journal
The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy
Published
2024-12-26
Primary Topic
Atomic and Subatomic Physics Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Дослідження умов формування газорідинного потоку при випуску плавки з конвертера

The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy
Atomic and Subatomic Physics Research
article

Дослідження умов формування газорідинного потоку при випуску плавки з конвертера

article en

Abstract

The study of the conditions for the formation of a gas-liquid flow during the tapping of molten metal from the converter is based on low-temperature modeling, aimed at analyzing the impact of the structural characteristics of the steel tapping channel. The use of inert gas (argon) enabled the creation of a protective gas shell that reduces the contact of the metal with atmospheric oxygen, lowering its content in the flow to 1–3%. Based on the experiments, a classification of blowing regimes and empirical dependencies were developed to describe the interaction between the gas and the liquid. It was established that the minimum oxygen concentration in the gas phase (1–3%) is achieved with an argon flow of 10–20% of the maximum. This maintains the efficiency of the protective shell at 95%. Further increases in the argon flow lead to the expansion of the flow's opening angle, negatively impacting its organization. Increasing the number of nozzles improves flow stability: with six nozzles, the oxygen concentration remains below 10.5%, even with high gas flow rates. Experiments on a flat tapping channel model revealed a dependence between the gas flow, liquid level, and the depth of the vortex. Increasing the gas flow with a high liquid level contributes to the stability of the interfacial surface, whereas reducing the liquid level leads to an increase in vortex depth and deterioration of the flow organization. The experiments were conducted on a laboratory setup simulating the tapping process, accounting for geometric and dynamic similarity. Technically pure argon with an oxygen content of up to 0.7% was used. The main parameters for analysis included gas flow rate, liquid level, relative vortex depth, and flow opening angle. To assess the effectiveness of the gas shell, oxygen concentration was analyzed using a gas analyzer. The proposed optimal conditions include controlling the argon flow rate, liquid level, and the number of nozzles. It was established that an argon flow rate of 0.05–0.125 m³/min ensures effective protection of the melt, and an optimal flow opening angle of up to 3° contributes to efficiency levels of 92–99%. The obtained results are of significant practical importance for improving the tapping process, refining, and reducing steel oxidation. The developed dependencies allow for more accurate determination of blowing parameters and optimization of the tapping channel design, thereby enhancing the efficiency of metallurgical processes

The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy
Openalex Percentile: Top 59%
Atomic and Subatomic Physics Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.