Validity and Short-Term Repeatability of a Novel Hand-Held Respiratory Health Meter for the Assessment of Dynamic Maximal Respiratory Pressures in Healthy Young Adults

Herkko Ryynänen,1,2 Anssi Sovijärvi,3 Ilpo Kuronen,4 Essi K Ahokas,1 Maarit Valtonen,5 Johanna K Ihalainen,1 Juhani Multanen1,6 1Faculty of Sport and Health Sciences, University of Jyväskylä, Jyväskylä, Finland; 2Finnish Lung Health Association, Helsinki, Finland; 3Department of Clinical Physiology, University of Helsinki, Helsinki, Finland; 4Reagena Ltd., Toivala, Finland; 5Finnish Institute of High Performance Sport KIHU, Jyväskylä, Finland; 6South-Eastern Finland University of Applied Sciences, Savonlinna, FinlandCorrespondence: Herkko Ryynänen, Faculty of Sport and Health Sciences, University of Jyväskylä, PO Box 35, Jyväskylä, Finland, Tel +358 40 7030231, Email [email protected]: Measuring maximal airway pressure is an essential part of the assessment of respiratory functions. Portable handheld devices have made clinical measurements more available, but reliable and user-friendly devices for non-clinical use remain rare. This study sought to determine the validity and short-term repeatability of measurements of dynamic maximal inspiratory pressure (dMIP) and dynamic maximal expiratory pressure (dMEP) by using a novel self-administered respiratory health meter (WellO2-RHM) in asymptomatic young adults.Patients and Methods: dMIP and dMEP were measured with WellO2-RHM in asymptomatic adult volunteers (n=26, 15 male and 11 female, age 26– 41 years). These values were compared with quasi-static maximal inspiratory pressure (MIP) and maximal expiratory pressure (MEP) obtained from the same volunteers using another respiratory manometer (MicroRPM). The measurements of dMIP and dMEP with WellO2-RHM were repeated in the same individuals at an interval of one week for assessment of their short-term repeatability.Results: The Pearson correlation coefficients of dMIP and dMEP values with MIP and MEP values were high (r=0.840, p< 0.001; r=0.849, p< 0.001, respectively). The dMIP and dMEP values were consistently lower than the quasi-static MIP and MEP values in the same individuals. The short-term repeatability of the dMIP and dMEP in one week interval proved to be moderately good in terms of the coefficient of variation (CV), the intraclass correlation coefficient (ICC), the standard error of measurement (SEm) and minimal detectable change (MDC) (10.0%, 0.825, p< 0.001, 7 cmH2O and 20 cmH2O and 9.1%, 0.895, p< 0.001, 12 cmH2O and 34 cmH2O, respectively).Conclusion: The results indicate that the WellO2-RHM is a valid and repeatable method for the assessment of dMIP and dMEP in asymptomatic young adults, but the absolute values are lower than those obtained with devices measuring quasi-static MIP and MEP. The findings suggest that WellO2-RHM can be used for self-monitoring of the effects of respiratory muscle training in healthy young adults.Keywords: breathing, respiratory muscles, assessment, maximal airway pressures, short-term repeatability

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-06-01
Primary Topic
Laser Design and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validity and Short-Term Repeatability of a Novel Hand-Held Respiratory Health Meter for the Assessment of Dynamic Maximal Respiratory Pressures in Healthy Young Adults

SHILAP Revista de lepidopterología
Laser Design and Applications
article

Validity and Short-Term Repeatability of a Novel Hand-Held Respiratory Health Meter for the Assessment of Dynamic Maximal Respiratory Pressures in Healthy Young Adults

article en

Abstract

Herkko Ryynänen,1,2 Anssi Sovijärvi,3 Ilpo Kuronen,4 Essi K Ahokas,1 Maarit Valtonen,5 Johanna K Ihalainen,1 Juhani Multanen1,6 1Faculty of Sport and Health Sciences, University of Jyväskylä, Jyväskylä, Finland; 2Finnish Lung Health Association, Helsinki, Finland; 3Department of Clinical Physiology, University of Helsinki, Helsinki, Finland; 4Reagena Ltd., Toivala, Finland; 5Finnish Institute of High Performance Sport KIHU, Jyväskylä, Finland; 6South-Eastern Finland University of Applied Sciences, Savonlinna, FinlandCorrespondence: Herkko Ryynänen, Faculty of Sport and Health Sciences, University of Jyväskylä, PO Box 35, Jyväskylä, Finland, Tel +358 40 7030231, Email [email protected]: Measuring maximal airway pressure is an essential part of the assessment of respiratory functions. Portable handheld devices have made clinical measurements more available, but reliable and user-friendly devices for non-clinical use remain rare. This study sought to determine the validity and short-term repeatability of measurements of dynamic maximal inspiratory pressure (dMIP) and dynamic maximal expiratory pressure (dMEP) by using a novel self-administered respiratory health meter (WellO2-RHM) in asymptomatic young adults.Patients and Methods: dMIP and dMEP were measured with WellO2-RHM in asymptomatic adult volunteers (n=26, 15 male and 11 female, age 26– 41 years). These values were compared with quasi-static maximal inspiratory pressure (MIP) and maximal expiratory pressure (MEP) obtained from the same volunteers using another respiratory manometer (MicroRPM). The measurements of dMIP and dMEP with WellO2-RHM were repeated in the same individuals at an interval of one week for assessment of their short-term repeatability.Results: The Pearson correlation coefficients of dMIP and dMEP values with MIP and MEP values were high (r=0.840, p< 0.001; r=0.849, p< 0.001, respectively). The dMIP and dMEP values were consistently lower than the quasi-static MIP and MEP values in the same individuals. The short-term repeatability of the dMIP and dMEP in one week interval proved to be moderately good in terms of the coefficient of variation (CV), the intraclass correlation coefficient (ICC), the standard error of measurement (SEm) and minimal detectable change (MDC) (10.0%, 0.825, p< 0.001, 7 cmH2O and 20 cmH2O and 9.1%, 0.895, p< 0.001, 12 cmH2O and 34 cmH2O, respectively).Conclusion: The results indicate that the WellO2-RHM is a valid and repeatable method for the assessment of dMIP and dMEP in asymptomatic young adults, but the absolute values are lower than those obtained with devices measuring quasi-static MIP and MEP. The findings suggest that WellO2-RHM can be used for self-monitoring of the effects of respiratory muscle training in healthy young adults.Keywords: breathing, respiratory muscles, assessment, maximal airway pressures, short-term repeatability

SHILAP Revista de lepidopterología
Washington Department of Social and Health Services (US)
Openalex Percentile: Top 52%
Laser Design and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.