Study results of the stress-strain states of the crown parts of molars restored with composite, ceramic and zirconium onlays

The relevance of the research is determined by the significant need for effective restorative treatment of caries decayed teeth. The purpose of the study is comparison of the stress-strain states in simulated models of non-homogeneous composite structural elements for typical geometric characteristics of onlays made of composite, ceramic, and zirconium dioxide in the restoration of the decayed mandibular molar. Computer simulation models of biomechanical systems were obtained by digital scanning of the mandibular molar in STEP format. Control was carried out in the form of numerical characteristics and graphical visualization in the EXOCAD program. The numerical method of finite elements, information technologies and program codes of the ANSYS Workbench 12.1 system were used to solve applied problems of biomechanics. After testing the developed discrete models, they were checked for adequacy and coincidence of numerical results in areas of high voltage gradients using the tools and methods of the ANSYS 12.1 code system. The maximum displacements, gradients, and amplitudes of the Mises-equivalent stress in the structural elements of each biomechanical system were evaluated. The stress values were calculated using the method of linear scaling of the results of the numerical solution of the boundary value problems of the theory of elasticity for small deformations to correspond to the functional force load of the mandibular molar of 100 N. The estimated values of the coefficients of the strength reserve of the structural elements were calculated as the ratio of the strength limit values to the maximum calculated values of the Mises-equivalent stress, scaled by a coefficient of 10 for a force load of 100 N. It was established that the largest voltage gradients are registered at the border of the cement layer. However, the nature of force transmission, as well as stress distribution, was different for different structural materials. The maximum stress was observed in the model with a composite onlay in the local area of the surface of the force load in the cement layer. For the ceramic onlay, the maximum stress was found on the lower support surface of contact with the onlay, where its values were 1.4 times higher than on other surfaces. The analysis of the zones of maximum stress for the zirconium onlay revealed their predominant localization in the center of its occlusal surface and in the zone of change in its spatial configuration at the border with cement. The highest stress values, along with the lowest coefficients of safety margin, were found for the molar model restored with a composite onlay, which indicated the lowest endurance of this material to functional load. While the zirconium onlay provided optimal stress distribution and it was characterized by the largest safety factor, which makes this method the most acceptable for molar restoration. The obtained results should be taken into account when choosing a material for the prosthetics of lateral teeth with onlays.

Institutions

Publication Details

Journal
The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy
Published
2024-12-26
Primary Topic
Nuclear reactor physics and engineering
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study results of the stress-strain states of the crown parts of molars restored with composite, ceramic and zirconium onlays

The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy
Nuclear reactor physics and engineering
article

Study results of the stress-strain states of the crown parts of molars restored with composite, ceramic and zirconium onlays

article en

Abstract

The relevance of the research is determined by the significant need for effective restorative treatment of caries decayed teeth. The purpose of the study is comparison of the stress-strain states in simulated models of non-homogeneous composite structural elements for typical geometric characteristics of onlays made of composite, ceramic, and zirconium dioxide in the restoration of the decayed mandibular molar. Computer simulation models of biomechanical systems were obtained by digital scanning of the mandibular molar in STEP format. Control was carried out in the form of numerical characteristics and graphical visualization in the EXOCAD program. The numerical method of finite elements, information technologies and program codes of the ANSYS Workbench 12.1 system were used to solve applied problems of biomechanics. After testing the developed discrete models, they were checked for adequacy and coincidence of numerical results in areas of high voltage gradients using the tools and methods of the ANSYS 12.1 code system. The maximum displacements, gradients, and amplitudes of the Mises-equivalent stress in the structural elements of each biomechanical system were evaluated. The stress values were calculated using the method of linear scaling of the results of the numerical solution of the boundary value problems of the theory of elasticity for small deformations to correspond to the functional force load of the mandibular molar of 100 N. The estimated values of the coefficients of the strength reserve of the structural elements were calculated as the ratio of the strength limit values to the maximum calculated values of the Mises-equivalent stress, scaled by a coefficient of 10 for a force load of 100 N. It was established that the largest voltage gradients are registered at the border of the cement layer. However, the nature of force transmission, as well as stress distribution, was different for different structural materials. The maximum stress was observed in the model with a composite onlay in the local area of the surface of the force load in the cement layer. For the ceramic onlay, the maximum stress was found on the lower support surface of contact with the onlay, where its values were 1.4 times higher than on other surfaces. The analysis of the zones of maximum stress for the zirconium onlay revealed their predominant localization in the center of its occlusal surface and in the zone of change in its spatial configuration at the border with cement. The highest stress values, along with the lowest coefficients of safety margin, were found for the molar model restored with a composite onlay, which indicated the lowest endurance of this material to functional load. While the zirconium onlay provided optimal stress distribution and it was characterized by the largest safety factor, which makes this method the most acceptable for molar restoration. The obtained results should be taken into account when choosing a material for the prosthetics of lateral teeth with onlays.

The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy
National Technical University of Ukraine “Igor Sikorsky Kyiv Polytechnic Institute” (UA)
Sustainable cities and communities
Openalex Percentile: Top 22%
Nuclear reactor physics and engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Study results of the stress-strain states of the crown parts of molars restored with composite, ceramic and zirconium onlays · The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy (2024) | TGRS Research Map | TGRS