Percutaneous Vertebroplasty Using GeneX® in Osteoporotic Vertebral Compression Fractures: A Case Report

Taibang Chen, Lei Cui, Di Du Department of Orthopaedic Surgery of 920th Hospital of Joint Logistics Support Force, Kunming, People’s Republic of ChinaCorrespondence: Taibang Chen, Email [email protected]: GeneX® allows adsorption and aggregation of molecules and proteins to promote bone formation. According to reports in the literature, it is used in bone defect reconstruction and percutaneous vertebroplasty to promote bone formation.Case Report: We designed a prospective cohort study to evaluate the outcomes following of percutaneous vertebroplasty using GeneX in patients with osteoporotic vertebral compression fractures. Vertebroplasty was performed at seven vertebrae in the first seven patients. Overall, there were four leaks in four (57%) of the seven patients. Asymptomatic leak of the GeneX material into the intradiscal and paravertebral structures at the treated vertebral level was observed in three patients (43%). However, the material leaked into the intradural and epidural space in the seventh patient (14%), causing severe neurological deficits. Primary diagnosis was bone cement implantation syndrome. The patient’s neurological status improved gradually during the month after surgery. She was able to resume her activities of daily living and had regained her urinary function by 3 months after surgery.Conclusion: Owing to its physicochemical characteristics, even with sophisticated surgical techniques, GeneX cannot be recommended for use in percutaneous vertebroplasty for OVCF. The long-term safety and efficacy of GeneX need to be further validated through Phase II clinical trials. Lumbar cistern drainage can significantly improve neurological deficits in patients caused by GeneX implantation syndrome.Keywords: vertebroplasty, osteoporosis, bone cements, fractures, bone

Institutions

Publication Details

Journal
Dove Medical Press (Taylor and Francis Group)
Published
2025-08-14
Primary Topic
Magnetic confinement fusion research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Percutaneous Vertebroplasty Using GeneX® in Osteoporotic Vertebral Compression Fractures: A Case Report

Dove Medical Press (Taylor and Francis Group)
Magnetic confinement fusion research
article

Percutaneous Vertebroplasty Using GeneX® in Osteoporotic Vertebral Compression Fractures: A Case Report

article en

Abstract

Taibang Chen, Lei Cui, Di Du Department of Orthopaedic Surgery of 920th Hospital of Joint Logistics Support Force, Kunming, People’s Republic of ChinaCorrespondence: Taibang Chen, Email [email protected]: GeneX® allows adsorption and aggregation of molecules and proteins to promote bone formation. According to reports in the literature, it is used in bone defect reconstruction and percutaneous vertebroplasty to promote bone formation.Case Report: We designed a prospective cohort study to evaluate the outcomes following of percutaneous vertebroplasty using GeneX in patients with osteoporotic vertebral compression fractures. Vertebroplasty was performed at seven vertebrae in the first seven patients. Overall, there were four leaks in four (57%) of the seven patients. Asymptomatic leak of the GeneX material into the intradiscal and paravertebral structures at the treated vertebral level was observed in three patients (43%). However, the material leaked into the intradural and epidural space in the seventh patient (14%), causing severe neurological deficits. Primary diagnosis was bone cement implantation syndrome. The patient’s neurological status improved gradually during the month after surgery. She was able to resume her activities of daily living and had regained her urinary function by 3 months after surgery.Conclusion: Owing to its physicochemical characteristics, even with sophisticated surgical techniques, GeneX cannot be recommended for use in percutaneous vertebroplasty for OVCF. The long-term safety and efficacy of GeneX need to be further validated through Phase II clinical trials. Lumbar cistern drainage can significantly improve neurological deficits in patients caused by GeneX implantation syndrome.Keywords: vertebroplasty, osteoporosis, bone cements, fractures, bone

Dove Medical Press (Taylor and Francis Group)
Institute for Nuclear Research (RU)
Good health and well-being
Openalex Percentile: Top 61%
Magnetic confinement fusion research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Percutaneous Vertebroplasty Using GeneX® in Osteoporotic Vertebral Compression Fractures: A Case Report · Dove Medical Press (Taylor and Francis Group) (2025) | TGRS Research Map | TGRS