Effect of humidity on the stiffness and hysteresis of composite 3D Printed paediatric prosthetic foot coupon samples

This research investigates the impact of ageing and humidity on the mechanical properties, specifically stiffness and hysteresis, of composite 3D printed paediatric prosthetic foot coupon samples. Understanding these effects is essential for ensuring the durability and performance of 3D Printed prosthetic devices in varying environmental conditions. A Markforged Mark 2 (Markforged Inc., Massachusetts) 3D printer was used to fabricate samples from Onyx, reinforced with carbon fibre. Compression testing was conducted, adapted from the ISO 10328 standard to evaluate the samples under conditions that simulate real-world use. Microscopy analysis was used for visual inspection of the samples post-testing. Results indicate that both stiffness and hysteresis properties of the composite samples deteriorate significantly with increased humidity exposure. Stiffness of the samples decreased by approximately 30% after 90 days, and hysteresis efficiency declined from 83% to 72%, reflecting a reduction in energy return capability. These findings highlight the importance of understanding how the mechanical properties of composite 3D printed paediatric prosthetic components change over time, especially under varying environmental conditions. The observed reductions in stiffness and hysteresis efficiency demonstrate the negative impacts on prosthetic performance and durability, and the effect this could have on the end user. This research also emphasises the necessity of investigating methods to maintain the initial mechanical properties, such as developing protective coatings or improved material formulations, to ensure the long-term reliability and effectiveness of paediatric prosthetic devices.

Publication Details

Journal
Bournemouth University Research Online (Bournemouth University)
Published
2024-10-04
Primary Topic
Magnetic confinement fusion research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of humidity on the stiffness and hysteresis of composite 3D Printed paediatric prosthetic foot coupon samples

Bournemouth University Research Online (Bournemouth University)
Magnetic confinement fusion research
article

Effect of humidity on the stiffness and hysteresis of composite 3D Printed paediatric prosthetic foot coupon samples

article en

Abstract

This research investigates the impact of ageing and humidity on the mechanical properties, specifically stiffness and hysteresis, of composite 3D printed paediatric prosthetic foot coupon samples. Understanding these effects is essential for ensuring the durability and performance of 3D Printed prosthetic devices in varying environmental conditions. A Markforged Mark 2 (Markforged Inc., Massachusetts) 3D printer was used to fabricate samples from Onyx, reinforced with carbon fibre. Compression testing was conducted, adapted from the ISO 10328 standard to evaluate the samples under conditions that simulate real-world use. Microscopy analysis was used for visual inspection of the samples post-testing. Results indicate that both stiffness and hysteresis properties of the composite samples deteriorate significantly with increased humidity exposure. Stiffness of the samples decreased by approximately 30% after 90 days, and hysteresis efficiency declined from 83% to 72%, reflecting a reduction in energy return capability. These findings highlight the importance of understanding how the mechanical properties of composite 3D printed paediatric prosthetic components change over time, especially under varying environmental conditions. The observed reductions in stiffness and hysteresis efficiency demonstrate the negative impacts on prosthetic performance and durability, and the effect this could have on the end user. This research also emphasises the necessity of investigating methods to maintain the initial mechanical properties, such as developing protective coatings or improved material formulations, to ensure the long-term reliability and effectiveness of paediatric prosthetic devices.

Bournemouth University Research Online (Bournemouth University)
Affordable and clean energy
Openalex Percentile: Top 78%
Magnetic confinement fusion research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effect of humidity on the stiffness and hysteresis of composite 3D Printed paediatric prosthetic foot coupon samples · Bournemouth University Research Online (Bournemouth University) (2024) | TGRS Research Map | TGRS