Analysis and optimization of heat dissipation of gas mainframe case based on field synergy principle

In order to ensure the safe and stable operation of gas turbine units, and grasp the heat transfer mechanism of the ventilation system of the mainframe housing, a study on the ventilation and heat dissipation of the main engine box of gas turbine units was carried out. Based on the principle of field synergy, the internal flow field, temperature field and heat dissipation performance of key equipments in the mainframe cabinet were analysed, and an optimized scheme for adding a flow-guiding device was proposed. The results show that the volume of the high-temperature area inside the mainframe housing is 7.6%, mainly concentrated near the gas turbine shaft component, which is the main heat source inside the mainframe housing, with an average external surface temperature of 86.94 <inline-formula><alternatives><math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M1"><mo>℃</mo></math><graphic specific-use="big" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="alternativeImage/A3C3F330-1450-42b4-9B12-7F5928EB8023-M001.jpg"><?fx-imagestate width="2.79399991" height="2.45533323"?></graphic><graphic specific-use="small" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="alternativeImage/A3C3F330-1450-42b4-9B12-7F5928EB8023-M001c.jpg"><?fx-imagestate width="2.79399991" height="2.45533323"?></graphic></alternatives></inline-formula>. After the installation of a 50° flow-guiding device, the volume of the high-temperature area inside the mainframe housing is reduced to 5.1%, and the average external surface temperature of the gas turbine shaft is reduced to 81.98 <inline-formula><alternatives><math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M2"><mo>℃</mo></math><graphic specific-use="big" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="alternativeImage/A3C3F330-1450-42b4-9B12-7F5928EB8023-M001.jpg"><?fx-imagestate width="2.79399991" height="2.45533323"?></graphic><graphic specific-use="small" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="alternativeImage/A3C3F330-1450-42b4-9B12-7F5928EB8023-M001c.jpg"><?fx-imagestate width="2.79399991" height="2.45533323"?></graphic></alternatives></inline-formula>. The heat dissipation effect is significantly improved.

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-04-01
Primary Topic
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis and optimization of heat dissipation of gas mainframe case based on field synergy principle

SHILAP Revista de lepidopterología
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
article

Analysis and optimization of heat dissipation of gas mainframe case based on field synergy principle

article en

Abstract

In order to ensure the safe and stable operation of gas turbine units, and grasp the heat transfer mechanism of the ventilation system of the mainframe housing, a study on the ventilation and heat dissipation of the main engine box of gas turbine units was carried out. Based on the principle of field synergy, the internal flow field, temperature field and heat dissipation performance of key equipments in the mainframe cabinet were analysed, and an optimized scheme for adding a flow-guiding device was proposed. The results show that the volume of the high-temperature area inside the mainframe housing is 7.6%, mainly concentrated near the gas turbine shaft component, which is the main heat source inside the mainframe housing, with an average external surface temperature of 86.94 <inline-formula><alternatives><math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M1"><mo>℃</mo></math><graphic specific-use="big" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="alternativeImage/A3C3F330-1450-42b4-9B12-7F5928EB8023-M001.jpg"><?fx-imagestate width="2.79399991" height="2.45533323"?></graphic><graphic specific-use="small" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="alternativeImage/A3C3F330-1450-42b4-9B12-7F5928EB8023-M001c.jpg"><?fx-imagestate width="2.79399991" height="2.45533323"?></graphic></alternatives></inline-formula>. After the installation of a 50° flow-guiding device, the volume of the high-temperature area inside the mainframe housing is reduced to 5.1%, and the average external surface temperature of the gas turbine shaft is reduced to 81.98 <inline-formula><alternatives><math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M2"><mo>℃</mo></math><graphic specific-use="big" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="alternativeImage/A3C3F330-1450-42b4-9B12-7F5928EB8023-M001.jpg"><?fx-imagestate width="2.79399991" height="2.45533323"?></graphic><graphic specific-use="small" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="alternativeImage/A3C3F330-1450-42b4-9B12-7F5928EB8023-M001c.jpg"><?fx-imagestate width="2.79399991" height="2.45533323"?></graphic></alternatives></inline-formula>. The heat dissipation effect is significantly improved.

SHILAP Revista de lepidopterología
Affordable and clean energy
Openalex Percentile: Top 52%
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis and optimization of heat dissipation of gas mainframe case based on field synergy principle · SHILAP Revista de lepidopterología (2025) | TGRS Research Map | TGRS