Оптимізація технологічних режимів ваграночної плавки за критерієм максимуму температури горіння

The object of research is the combustion temperature in the cupola furnace. The problem under study was the complexity of predicting the temperature as a function of the control parameters of the melting. In the study, the control parameters were selected as the temperature of the air heating blown into the tuyeres and the completeness of fuel combustion. Using orthogonal experimental planning, a mathematical model was constructed in the form of a second-order polynomial, which allowed to identify the patterns of influence of each control factor on the resulting value – the combustion temperature. The resulting mathematical model allowed to find out that both input variables are significant. However, if the nature of the influence of the air heating temperature on the combustion temperature is linear, then the completeness of combustion affects nonlinearly. The accuracy of the model turned out to be satisfactory, because all experimental data fell within the confidence intervals with a confidence probability of P=0.99. This allows to state the possibility of using the constructed model to predict the combustion temperature within the planning area. The ridge analysis of the response surface established that the theoretical maximum value of the combustion temperature at the boundary of the planning area is about 3000 °C. This corresponds to the values of the input variables Tair≈1120 °C and η0≈82 %. However, due to the fact that ensuring the air heating temperature at the level of 1120 °C may encounter technical complexity of implementation, the following values of the input variables can be recommended: Tair=783–1060 °C, η0=71–80. They provide combustion temperatures in the range of 2690–2980 °C, i. e. values close to the suboptimal one determined by the ridge analysis. These data allow making adjustments to the melting process, including being used for further searching for optimal melting control. The obtained solutions can be used in iron foundry shops of industrial enterprises equipped with cupola furnaces.

Publication Details

Journal
The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy
Published
2025-05-07
Primary Topic
Stonefly species taxonomy and ecology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Оптимізація технологічних режимів ваграночної плавки за критерієм максимуму температури горіння

The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy
Stonefly species taxonomy and ecology
article

Оптимізація технологічних режимів ваграночної плавки за критерієм максимуму температури горіння

article en

Abstract

The object of research is the combustion temperature in the cupola furnace. The problem under study was the complexity of predicting the temperature as a function of the control parameters of the melting. In the study, the control parameters were selected as the temperature of the air heating blown into the tuyeres and the completeness of fuel combustion. Using orthogonal experimental planning, a mathematical model was constructed in the form of a second-order polynomial, which allowed to identify the patterns of influence of each control factor on the resulting value – the combustion temperature. The resulting mathematical model allowed to find out that both input variables are significant. However, if the nature of the influence of the air heating temperature on the combustion temperature is linear, then the completeness of combustion affects nonlinearly. The accuracy of the model turned out to be satisfactory, because all experimental data fell within the confidence intervals with a confidence probability of P=0.99. This allows to state the possibility of using the constructed model to predict the combustion temperature within the planning area. The ridge analysis of the response surface established that the theoretical maximum value of the combustion temperature at the boundary of the planning area is about 3000 °C. This corresponds to the values of the input variables Tair≈1120 °C and η0≈82 %. However, due to the fact that ensuring the air heating temperature at the level of 1120 °C may encounter technical complexity of implementation, the following values of the input variables can be recommended: Tair=783–1060 °C, η0=71–80. They provide combustion temperatures in the range of 2690–2980 °C, i. e. values close to the suboptimal one determined by the ridge analysis. These data allow making adjustments to the melting process, including being used for further searching for optimal melting control. The obtained solutions can be used in iron foundry shops of industrial enterprises equipped with cupola furnaces.

The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy
Openalex Percentile: Top 44%
Stonefly species taxonomy and ecology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.