Enhanced Diagnostic Precision in Revisited Emergency Patients via Point-of-Care Ultrasound: A Tool for Emergency Department Quality Management

Kamonwon Ienghong,1 Sukanya Khemtong,1 Lap Woon Cheung,2,3 Korakot Apiratwarakul1 1Department of Emergency Medicine, Faculty of Medicine, Khon Kaen University, Khon Kaen, Thailand; 2Accident & Emergency Department, Princess Margaret Hospital, Kowloon, Hong Kong; 3Department of Emergency Medicine, Li ka Shing Faculty of Medicine, The University of Hong Kong, Pokfulam, Hong KongCorrespondence: Korakot Apiratwarakul, Department of Emergency Medicine, Faculty of Medicine, Khon Kaen University, 123 Mittraphap Road, Mueang Khon Kaen District, Khon Kaen, 40002, Thailand, Tel +66 89 416 3663, Fax +66 43 366 870, Email [email protected]: Unscheduled return visits to the emergency department (ED) were categorized into physician-related, illness-related, and patient-related factors, which are associated with an increased risk of adverse health outcomes, including patient dissatisfaction, infections, hospitalization, transfer to another facility, and mortality. Individuals within 48– 72 hours of the initial visit are deemed at elevated risk for diagnostic or management-related errors. The Point-of-care ultrasound (POCUS) may serve as a bedside tool to reduce medical errors by enhancing diagnostic precision. This study aims to determine the diagnostic accuracy of POCUS for detecting various illnesses in revisited patients in the emergency department.Patients and Methods: A retrospective observational study was conducted on unplanned revisits by patients to the emergency department within 72 hours, spanning the period from January 2023 to September 2024. Sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio were evaluated based on electronic emergency department medical records and ultrasound documentation.Results: Five hundred seventy patients were included in this study. POCUS demonstrated a diagnostic accuracy of 75.61% (95% CI 71.87, 79.09), a sensitivity of 81.87% (95% CI 77.65, 85.58), a specificity of 62.50% (95% CI 55.08, 69.51), a positive likelihood ratio of 2.18 (95% CI 1.80, 2.65), and a negative likelihood ratio of 0.29 (95% CI 0.23, 0.37).Conclusion: POCUS demonstrated greater diagnostic accuracy, which may enhance diagnostic precision in revisited patients with various illnesses.Keywords: precision medicine, ultrasound, revisit, emergency department, quality

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-03-01
Primary Topic
Hymenoptera taxonomy and phylogeny
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhanced Diagnostic Precision in Revisited Emergency Patients via Point-of-Care Ultrasound: A Tool for Emergency Department Quality Management

SHILAP Revista de lepidopterología
Hymenoptera taxonomy and phylogeny
article

Enhanced Diagnostic Precision in Revisited Emergency Patients via Point-of-Care Ultrasound: A Tool for Emergency Department Quality Management

article en

Abstract

Kamonwon Ienghong,1 Sukanya Khemtong,1 Lap Woon Cheung,2,3 Korakot Apiratwarakul1 1Department of Emergency Medicine, Faculty of Medicine, Khon Kaen University, Khon Kaen, Thailand; 2Accident & Emergency Department, Princess Margaret Hospital, Kowloon, Hong Kong; 3Department of Emergency Medicine, Li ka Shing Faculty of Medicine, The University of Hong Kong, Pokfulam, Hong KongCorrespondence: Korakot Apiratwarakul, Department of Emergency Medicine, Faculty of Medicine, Khon Kaen University, 123 Mittraphap Road, Mueang Khon Kaen District, Khon Kaen, 40002, Thailand, Tel +66 89 416 3663, Fax +66 43 366 870, Email [email protected]: Unscheduled return visits to the emergency department (ED) were categorized into physician-related, illness-related, and patient-related factors, which are associated with an increased risk of adverse health outcomes, including patient dissatisfaction, infections, hospitalization, transfer to another facility, and mortality. Individuals within 48– 72 hours of the initial visit are deemed at elevated risk for diagnostic or management-related errors. The Point-of-care ultrasound (POCUS) may serve as a bedside tool to reduce medical errors by enhancing diagnostic precision. This study aims to determine the diagnostic accuracy of POCUS for detecting various illnesses in revisited patients in the emergency department.Patients and Methods: A retrospective observational study was conducted on unplanned revisits by patients to the emergency department within 72 hours, spanning the period from January 2023 to September 2024. Sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio were evaluated based on electronic emergency department medical records and ultrasound documentation.Results: Five hundred seventy patients were included in this study. POCUS demonstrated a diagnostic accuracy of 75.61% (95% CI 71.87, 79.09), a sensitivity of 81.87% (95% CI 77.65, 85.58), a specificity of 62.50% (95% CI 55.08, 69.51), a positive likelihood ratio of 2.18 (95% CI 1.80, 2.65), and a negative likelihood ratio of 0.29 (95% CI 0.23, 0.37).Conclusion: POCUS demonstrated greater diagnostic accuracy, which may enhance diagnostic precision in revisited patients with various illnesses.Keywords: precision medicine, ultrasound, revisit, emergency department, quality

SHILAP Revista de lepidopterología
Good health and well-being
Openalex Percentile: Top 40%
Hymenoptera taxonomy and phylogeny
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Enhanced Diagnostic Precision in Revisited Emergency Patients via Point-of-Care Ultrasound: A Tool for Emergency Department Quality Management · SHILAP Revista de lepidopterología (2025) | TGRS Research Map | TGRS