Design and Validation of Data Glove with Flex Sensor and 9-Axis IMU to Assess Hand Dexterity

Hand-motion detection technology has seen a rise in popularity over the years, due to the advancement of virtual reality (VR) technology and robotics. The medical industry has also shown interest in the technology for its ability to help detect hand dexterity issues and track the rehabilitation process of stroke victims with reduced hand motor functionality. Existing studies focus on hardware and filter design with little implementation of real-time data and wireless communication. This study advances the state of the art by developing a precise, robust data glove that combines flex sensors with inertial measurement units (IMUs) and streams data over Bluetooth Low Energy (BLE). In a Unity 3D environment, a digital hand model is driven in real time by the glove, faithfully replicating the wearer’s movements. The prototype achieved an accuracy of around 97.85% with a latency of roughly 0.28 s, capturing even high-frequency motion events. Given its performance and versatility, the proposed architecture shows strong promise for a wide range of applications, including hand dexterity related applications.

Publication Details

Journal
Edinburgh Napier Research Repository (Edinburgh Napier University)
Published
2025-09-16
Primary Topic
Bryophyte Studies and Records
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Validation of Data Glove with Flex Sensor and 9-Axis IMU to Assess Hand Dexterity

Edinburgh Napier Research Repository (Edinburgh Napier University)
Bryophyte Studies and Records
article

Design and Validation of Data Glove with Flex Sensor and 9-Axis IMU to Assess Hand Dexterity

article en

Abstract

Hand-motion detection technology has seen a rise in popularity over the years, due to the advancement of virtual reality (VR) technology and robotics. The medical industry has also shown interest in the technology for its ability to help detect hand dexterity issues and track the rehabilitation process of stroke victims with reduced hand motor functionality. Existing studies focus on hardware and filter design with little implementation of real-time data and wireless communication. This study advances the state of the art by developing a precise, robust data glove that combines flex sensors with inertial measurement units (IMUs) and streams data over Bluetooth Low Energy (BLE). In a Unity 3D environment, a digital hand model is driven in real time by the glove, faithfully replicating the wearer’s movements. The prototype achieved an accuracy of around 97.85% with a latency of roughly 0.28 s, capturing even high-frequency motion events. Given its performance and versatility, the proposed architecture shows strong promise for a wide range of applications, including hand dexterity related applications.

Edinburgh Napier Research Repository (Edinburgh Napier University)
Openalex Percentile: Top 41%
Bryophyte Studies and Records
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.