Counteracting Downstream Effects Using Turbulence Promoters in Retrofit

One of the simplest strategies for retrofitting heat recovery networks with the goal of reducing energy consumption in a process is the implementation of turbulence promoters. However, an adverse effect of this measure in heat recovery networks is the generation of downstream temperature disturbances that impact the operation of equipment within the network. This study introduces the use of Perforated Twisted Tapes (PTT) in retrofit schemes to enhance thermal load while simultaneously mitigating adverse effects related to network structure. General thermohydraulic correlations have been developed to analyse the implementation of twist ratios between 2 and 7. Through a case study with multiple scenarios, it has been observed that when using higher-density promoters (with a twist ratio of 2), energy savings are reduced by 38.38 % due to adverse effects, resulting in net savings of 3.66 MW. In the case of using promoters with lower density (with a TR=7), the reduction in savings is 26.67 %, with net savings of 3.52 MW.

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-12-01
Primary Topic
Applied Advanced Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Counteracting Downstream Effects Using Turbulence Promoters in Retrofit

SHILAP Revista de lepidopterología
Applied Advanced Technologies
article

Counteracting Downstream Effects Using Turbulence Promoters in Retrofit

article en

Abstract

One of the simplest strategies for retrofitting heat recovery networks with the goal of reducing energy consumption in a process is the implementation of turbulence promoters. However, an adverse effect of this measure in heat recovery networks is the generation of downstream temperature disturbances that impact the operation of equipment within the network. This study introduces the use of Perforated Twisted Tapes (PTT) in retrofit schemes to enhance thermal load while simultaneously mitigating adverse effects related to network structure. General thermohydraulic correlations have been developed to analyse the implementation of twist ratios between 2 and 7. Through a case study with multiple scenarios, it has been observed that when using higher-density promoters (with a twist ratio of 2), energy savings are reduced by 38.38 % due to adverse effects, resulting in net savings of 3.66 MW. In the case of using promoters with lower density (with a TR=7), the reduction in savings is 26.67 %, with net savings of 3.52 MW.

SHILAP Revista de lepidopterología
Affordable and clean energy
Openalex Percentile: Top 45%
Applied Advanced Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.