Sudden pump stop may cause air release in oxygenators, ‘The Hammer Effect ’: An in vitro evaluation

Background: Oxygenators, as used in cardiopulmonary bypass (CPB) circuits, are components with good air removal properties. However, under some conditions the semipermeable characteristics of hollow fibers allow air to accidentally enter the blood side of the CPB circuit. This may occur when a fluid in motion is stopped suddenly by which the rapid change in momentum may cause a relative negative pressure drop, the so-called hammer effect. The hammer effect is not yet described in literature related to CPB. The aim of this in vitro study was to reproduce the hammer effect. Methods: The in vitro setup consisted of a CPB circuit with a fully occluded roller pump and one of four test oxygenators. The hammer test was performed by a sudden pump stop. The pressure wave was measured and after the test the residual air present in the oxygenator was forced into the arterial line and measured with a bubble detector. Results: We showed that a sudden pump stop could lead to the hammer effect, represented as a relative negative pressure drop in the arterial line. This hammer effect resulted in air release through the semipermeable fibers as we showed in two of the four tested brands of oxygenators. Conclusions: We conclude that the hammer effect may occur before connection of the CPB system to the patient, and this may result in air release into the arterial blood side of the oxygenator. The hammer effect can be caused by clamping of the tubing in combination with a centrifugal pump, or by suddenly stopping the roller pump. With this study we would like to raise awareness of the hammer effect.

Publication Details

Journal
Utrecht University Repository (Utrecht University)
Published
2025-03-01
Primary Topic
Education, Innovation and Language Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sudden pump stop may cause air release in oxygenators, ‘The Hammer Effect ’: An in vitro evaluation

Utrecht University Repository (Utrecht University)
Education, Innovation and Language Studies
article

Sudden pump stop may cause air release in oxygenators, ‘The Hammer Effect ’: An in vitro evaluation

article en

Abstract

Background: Oxygenators, as used in cardiopulmonary bypass (CPB) circuits, are components with good air removal properties. However, under some conditions the semipermeable characteristics of hollow fibers allow air to accidentally enter the blood side of the CPB circuit. This may occur when a fluid in motion is stopped suddenly by which the rapid change in momentum may cause a relative negative pressure drop, the so-called hammer effect. The hammer effect is not yet described in literature related to CPB. The aim of this in vitro study was to reproduce the hammer effect. Methods: The in vitro setup consisted of a CPB circuit with a fully occluded roller pump and one of four test oxygenators. The hammer test was performed by a sudden pump stop. The pressure wave was measured and after the test the residual air present in the oxygenator was forced into the arterial line and measured with a bubble detector. Results: We showed that a sudden pump stop could lead to the hammer effect, represented as a relative negative pressure drop in the arterial line. This hammer effect resulted in air release through the semipermeable fibers as we showed in two of the four tested brands of oxygenators. Conclusions: We conclude that the hammer effect may occur before connection of the CPB system to the patient, and this may result in air release into the arterial blood side of the oxygenator. The hammer effect can be caused by clamping of the tubing in combination with a centrifugal pump, or by suddenly stopping the roller pump. With this study we would like to raise awareness of the hammer effect.

Utrecht University Repository (Utrecht University)
Openalex Percentile: Top 37%
Education, Innovation and Language Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Sudden pump stop may cause air release in oxygenators, ‘The Hammer Effect ’: An in vitro evaluation · Utrecht University Repository (Utrecht University) (2025) | TGRS Research Map | TGRS